71
5) The Water Supply Pipe is located right under the Spray Tube. Remove the Water
Supply Pipe from the Evaporator, pinch and shift the Hose Clamp, and disconnect
the Hose.
6) The Spray Guide is located under the Water Supply Pipe. Pull off the Spray Guide
from the Evaporator Plate.
7) Re
fi
t the removed parts in the reverse order of the removal procedure. Check for
water leaks.
IMPORTANT
Fit the Spray Guide securely and tightly on the Evaporator
fi
n. Otherwise,
cloudy or irregular ice cubes or performance reduction may be caused.
8) Plug in the icemaker or connect the power source.
23. DOOR
1) Remove the Top Panel.
2) Move the Door to
fi
t the Door Shaft in the inlet of the Door Channel. Slide up the
Door to release it from the Door Channel.
3) Re
fi
t the Door in the reverse order of the removal procedure. Do not forget to
fi
t the
Collar on the Door Shaft, or the Door will not open or close smoothly.
Fig. 32