21
1. Icemaker
• Icemaker water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" OD
copper tubing is recommended for the icemaker water supply line.
• An icemaker water supply line shut-off valve and drain valve should be installed.
• Icemaker drain outlet is 3/4" FPT. A minimum of 3/4" OD hard pipe is recommended
for the icemaker drain line. Condensation drain outlet is 3/8" OD stainless tube. The
condensation drain line can be connected to the icemaker drain line or can be run
separately.
Fig. 12
KM-650MAH and KM-650MRH
Separate piping to approved drain.
Leave a two-inch (5 cm) vertical air
gap between the end of each pipe
and the drain.
Icemaker Water Supply Line
Shut-Off Valve
Icemaker Water Supply Line
Drain Valve
Icemaker
Icemaker
Water Supply
Inlet
1/2" FPT
Bin Drain Outlet
3/4" FPT
Two-inch
(5 cm) air
gap
Floor Drain
Icemaker
Drain Outlet
3/4" FPT
Bin
Condensation
Drain Outlet
3/8" OD Stainless
Tube