F. Installation of Remote Condenser Unit
WARNING
1. Installation of remote condenser unit must be performed by properly trained
and certified service personnel.
2. Failure to install the equipment within these guidelines may adversely affect
safety, performance, component life, and warranty coverage.
1. Checks Before Installation
1) Remove the shipping carton, tape, and packing material.
2) Check that the refrigerant lines do not rub or touch lines or other surfaces, and that the
fan blade moves freely.
2. Location
CAUTION
1. The remote condenser unit is intended for outdoor use. Normal operating
ambient temperature should be within -20°F to +122°F (-29°C to +50°C).
Operation of the remote condenser unit, for extended periods, outside of this
normal temperature range may affect icemaker performance.
2. The maximum line length for the standard line sizes and refrigerant charge
is 66 feet. With larger line sizes and additional refrigerant, the maximum line
length is 100 feet. For details, see "II.F.5. Line Set Exceeding 66 Feet."
3. The maximum vertical distance between the remote condenser unit and the
icemaker is 33 feet above or 10 feet below the icemaker. These distances are
measured fitting to fitting. See Fig. 4.
The remote condenser unit must be positioned in a permanent site under the following
guidelines:
• A firm and flat site.
• A dry and well ventilated area with 24" (61 cm) clearance in both front and rear for
proper air circulation and ease of maintenance and/or service should they be required.
See Fig. 5.
Fig. 4
Min. 24" (61 cm) Clearance
Air
Air
Fig. 5
Icemaker
Remote
Condenser
Unit
Service Loop