65
7. KM-515MRH with URC-5F
Specification Sheet
AC SUPPLY VOLTAGE
115/60/1
AMPERAGE
11.3A (5 Min. Freeze AT 104°F/WT 80°F)
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
ELECTRIC & WATER CONSUMPTION 90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
1090(5.8)
1000(4.9)
WATER gal./24HR (gal./100 lbs.)
94(20.8)
198(40.4)
ICE PRODUCTION PER CYCLE
10.3 lbs. (4.7 kg) 480pcs.
BIN CONTROL SYSTEM
Thermostat or Mechanical Bin Control
TOTAL REFRIGERANT CHARGE
R404A, 4 lbs. 4.8 oz. (1950g)
REFRIGERANT CHARGE BY UNIT
Icemaker 2 lbs. 6.8 oz. Cond. Unit 1 lbs. 14 oz.
Performance Data
70/21
491
223
480
218
443
201
80/27
482
219
465
211
417
189
90/32
480
218
452
205
408
185
lbs./day kg./day
100/38
465
211
442
200
368
167
70/21
80/27
90/32
watts
100/38
70/21
198
0.75
168
0.64
153
0.58
80/27
175
0.66
128
0.48
128
0.49
90/32
168
0.64
94
0.36
88
0.33
gal./day m3/day
100/38
133
0.50
93
0.35
82
0.31
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
216
15.2
234
16.4
252
17.7
80/27
230
16.1
257
18.1
272
19.1
90/32
234
16.4
277
19.5
294
20.6
PSIG kg/cm2G
100/38
235
16.6
281
19.8
309
21.7
70/21
47
3.3
50
3.5
52
3.6
80/27
49
3.5
54
3.8
54
3.8
90/32
50
3.5
57
4.0
58
4.1
PSIG kg/cm2G
100/38
50
3.5
57
4.0
59
4.1
8,500 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
1,400 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
CONDENSER VOLUME
43 CU. IN (URC-5F)
TOTAL HEAT OF REJECTION FROM COMPRESSOR
3.6
2.7
2.7
HEAD PRESSURE
SUCTION PRESSURE
TOTAL HEAT OF REJECTION FROM CONDENSER
HARVEST CYCLE TIME
5.0
4.3
4.1
4.5
3.4
3.6
4.3
2.7
2.7
32
27
31
34
28
31
36
1031
1097
1150
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
26
27
30
27
29
1020
1061
1091
1026
1090
1121
APPROXIMATE ELECTRIC
CONSUMPTION
1000
APPROXIMATE ICE PRODUCTION
PER 24 HR.
AMBIENT TEMP.
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10
70/21
90/32
1026
1058
ENG.F-011.1.0205