46
C. Settings and Adjustments
NOTICE
Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact your
Hoshizaki Service Center.
1. Default Dip Switch Settings
The dip switches are factory-adjusted to the following positions for both the "E" and "G"
control boards:
a) "E" and "G" Control Board without Harvest Pump Timer Operation
"E" Control Board S4 Dip Switch No.
1
2
3
4
5
6
7
8
9
10
KM-320MAH, KM-320MWH
OFF OFF OFF ON ON ON OFF OFF OFF OFF
KM-515MAH, KM-515MWH, KM-515MRH
OFF OFF OFF OFF OFF OFF OFF OFF ON OFF
KM-600MAH, KM-650MAH, KM-650MWH
OFF OFF OFF OFF ON ON OFF OFF OFF OFF
KM-650MRH
OFF OFF OFF OFF ON ON OFF OFF ON OFF
KM-901MAH, KM-901MWH, KM-901MRH/3
ON OFF ON OFF ON ON OFF OFF OFF ON
KM-1100MAH, KM-1100MWH, KM-1100MRH OFF OFF OFF OFF ON ON ON OFF OFF OFF
KM-1340MAH
OFF OFF ON ON ON ON OFF OFF OFF OFF
KM-1340MWH, KM-1601MRH/3
OFF OFF ON OFF ON ON OFF OFF OFF ON
KM-1340MRH
OFF OFF ON OFF ON ON OFF OFF OFF OFF
b) "G" Control Board with Harvest Pump Timer Operation
S4 Dip Switch No.
1
2
3
4
5
6
7
8
9
10
KM-340MAH, KM-340MWH
OFF OFF ON OFF ON ON ON OFF ON OFF
KM-515MAH
OFF OFF OFF OFF ON ON ON OFF ON OFF
KM-650MAH, KM-650MRH
ON OFF OFF OFF ON ON ON OFF OFF OFF
KM-650MWH
OFF OFF OFF OFF ON ON ON OFF OFF OFF
KM-901MAH
OFF OFF ON OFF ON ON ON OFF OFF ON
S5 Dip Switch (Do Not Adjust)
"G" Control Board
Dip Switch No.
1
2
3
4
5
All Models
OFF OFF OFF OFF OFF
2. Harvest Timer (S4 dip switch 1 & 2)
Freeze Timer (9 & 10)
Pump-Out Frequency Control (5 & 6)
Pump-Out Timer (3 & 4)
Harvest Timer (1 & 2)
Factory Use (8)
Bin Control Selector (7) "E" Control Board
Harvest Pump Timer (7) "G" Control Board
(Do Not Adjust)
1
2
3
4
5
6
7
8
9
10
ON
S4 Dip Switch
"E" and "G" Control Boards
1
2
3
4
5
ON
Do Not Adjust
S5 Dip Switch
"G" Control Board Only
Refill Counter
(2 through 5)
Float Switch
Selector (1)