14. KM-901MRH with URC-9F
Specification Sheet
AC SUPPLY VOLTAGE
208-230/60/1 (3 wire with neutral) or 208-230/60/1
AMPERAGE
11.6A (5 Min. Freeze AT 104°F/WT 80°F)
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
ELECTRIC & WATER CONSUMPTION 90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
1770(5.4)
70/21(0.0)
WATER gal./24HR (gal./100 lbs.)
152(19.3)
10(0.0)
ICE PRODUCTION PER CYCLE
13.5 lbs. (6.1 kg) 720pcs.
BIN CONTROL SYSTEM
Thermostat or Mechanical Bin Control
TOTAL REFRIGERANT CHARGE
R404A, 9 lbs. 4 oz. (4200g)
REFRIGERANT CHARGE BY UNIT
Icemaker 5 lbs. 5 oz. Cond. Unit 3 lbs. 15 oz.
Performance Data
70/21
889
403
859
389
803
364
80/27
866
393
818
371
755
343
90/32
859
389
785
356
724
328
lbs./day kg./day
100/38
843
382
771
350
668
303
70/21
80/27
90/32
watts
100/38
70/21
246
0.93
219
0.83
194
0.74
80/27
225
0.85
182
0.69
165
0.63
90/32
219
0.83
152
0.57
131
0.50
gal./day m3/day
100/38
182
0.69
147
0.56
112
0.42
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
208
14.6
229
16.1
252
17.7
80/27
224
15.7
256
18.0
277
19.5
90/32
229
16.1
279
19.6
301
21.2
PSIG kg/cm2G
100/38
232
16.3
284
20.0
322
22.6
70/21
35
2.5
37
2.6
41
2.9
80/27
37
2.6
40
2.8
45
3.1
90/32
37
2.6
43
3.0
47
3.3
PSIG kg/cm2G
100/38
38
2.7
44
3.1
51
3.6
14,000 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
2,200 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
CONDENSER VOLUME
121 CU. IN (URC-9F)
APPROXIMATE ICE PRODUCTION
PER 24 HR.
AMBIENT TEMP.
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10
70/21
90/32
APPROXIMATE ELECTRIC
CONSUMPTION
1590
1643
1664
1630
1712
1705
1643
1770
1775
1630
1771
1780
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
18
20
21
19
21
23
20
22
24
20
23
26
HARVEST CYCLE TIME
4.3
3.9
3.6
4.0
3.4
3.2
3.9
2.9
2.7
TOTAL HEAT OF REJECTION FROM COMPRESSOR
3.4
2.8
2.4
HEAD PRESSURE
SUCTION PRESSURE
TOTAL HEAT OF REJECTION FROM CONDENSER