17
2) Move the Control Switch, on the Control Box,
to the “OFF” position.
3) Wait 3 minutes.
4) Close the Potable Water Supply Line Shut-
off Valve and open the Potable Water Supply
Line Drain Valve. See Fig. 4.
5) Allow the line to drain by gravity.
6) Attach compressed air or carbon dioxide
supply to the Potable Water Line Drain Valve.
7) Move the Control Switch to the “ICE”
position.
8) Blow the potable water line out using com-
pressed air or carbon dioxide.
[3] Drain the Potable Water Tank:
1) Turn off the power supply.
2) Move the Control Switch, on the Control Box,
to the “OFF” position.
3) Remove the Base Cover. See Fig. 5.
4) Remove the back end of the Pump Tubing,
and drain the Water Tank. See Fig. 7.
5) Replace the Pump Tubing and the
Base Cover in their correct positions.
6) Remove all ice from the Storage Bin,
and clean the Storage Bin.
7) Replace the Front Panel in its correct
position.
Fig. 7
Pump Tubing
Base Cover
Fig. 5
Do not pull out this end.
Pump Tubing
Содержание KM-280MAH
Страница 6: ...6 2 DIMENSIONS CONNECTIONS a KM 280MAH Unit inches mm ...
Страница 7: ...7 b KM 280MWH Unit inches mm ...
Страница 12: ...12 KM 280MWH Fig 4 KM 280MAH ...