![Hoshizaki KM-1601MRH/3 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/hoshizaki/km-1601mrh-3/km-1601mrh-3_service-manual_2165394025.webp)
25
C. Performance Data
1. KM-1601MRH with URC-21F
70/21
1508
684
1483
673
1399
634
80/27
1489
675
1450
658
1338
607
90/32
1483
673
1422
645
1320
599
lbs./day kg./day
100/38
1449
657
1398
634
1227
557
70/21
80/27
90/32
watts
100/38
70/21
483
1.83
418
1.58
363
1.37
80/27
434
1.64
334
1.26
296
1.12
90/32
418
1.58
263
1.00
217
0.82
gal./day m
3
/day
100/38
335
1.27
252
0.95
174
0.66
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
200
14.1
215
15.1
231
16.3
80/27
211
14.9
234
16.5
249
17.5
90/32
215
15.1
251
17.6
266
18.7
PSIG kg/cm
2
G
100/38
217
15.3
254
17.9
281
19.8
70/21
35
2.5
37
2.6
39
2.7
80/27
36
2.6
39
2.7
41
2.9
90/32
37
2.6
41
2.9
43
3.0
PSIG kg/cm
2
G
100/38
37
2.6
41
2.9
45
3.2
CONDENSER VOLUME
441 CU. IN (URC-21F)
Note: Pressure data is recorded at 5 minutes into freezing cycle.
The data not in
bold
should be used for reference only.
TOTAL HEAT OF REJECTION FROM CONDENSER
23,400 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
3,200 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
2.2
SUCTION PRESSURE
HARVEST CYCLE TIME
HEAD PRESSURE
4.1
3.4
4.6
2.5
27
24
24
27
2532
2577
2665
2660
26
27
28
30
2494
2514
2599
2670
2669
2450
2499
2514
23
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP.
(ºF/ºC)
50/10
70/21
90/32
24
24
25
2.8
5.3
3.7
4.6
3.6
2.8
4.8
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in
bold
should be used for reference only.
2. We reserve the right to make changes in specifications and design without prior
notice.