25
Problem
Possible Cause
Remedy
[1] Continued from
previous page.
j)
Water Supply Line
1. Water supply off and
water supply cycle does
not finish.
1. Check and get
recommended pressure.
2. Condenser water
pressure too low or off
and pressure control
opens and closes
frequently to finally
operate high
temperature safety.
2. Check and get
recommended pressure.
k) Water Solenoid
1. Mesh filter or orifice
gets clogged and water
supply cycle does not
finish.
1. Clean.
2. Coil winding opened.
2. Replace.
3. Wiring to water valve.
3. Check for loose
connection or open, and
replace.
l)
Controller Board
1. Defective.
1. See "II.B.5. Checking
the Controller Board."
[2]
a) Float Switch
1. Connector
disconnected.
1. Place in position.
2. Leads opened or
defective switch.
2. Check and replace.
3. Float does not move
freely.
3. Clean or replace.
b) Controller Board
1. Defective.
1. Replace.
c) Contactor
1. Open coil or contacts
worn.
1. Replace.
[3]
a) Wash Switch
1. WASH position.
1. Move to ICE position.
2. Bad contacts.
2. Check and replace.
b) High Pressure Control
1. Dirty air filter or
condenser.
1. Clean.
2. Ambient or condenser
water temperature too
warm.
2. Reduce temperature.
3. Refrigerant
overcharged.
3. Recharge.
4. Refrigerant line or
components plugged.
4. Clean and replace drier.
5. Fan not operating.
5. See chart A.[6]
Compressor will not
start or stops
operating.
Water continues to
be supplied, and the
icemaker will not
start.