26
Problem
Possible Cause
Remedy
[3]
c) Overload Protector
1. Bad contacts.
1. Check for continuity
and replace.
2. Voltage too low.
2. Increase voltage.
3. Refrigerant overcharged
or undercharged.
3. Recharge.
4. Line valve continues to
close in freeze cycle
and overload protector
operates.
4. Check line valve's
operation in freeze
cycle and replace.
d) Starter
1. Bad contacts.
1. Check and replace.
2. Coil winding opened.
2. Replace.
e) Start Capacitor or Run
Capacitor
1. Defective.
1. Replace.
f) Magnetic Contactor
1. Bad contacts.
1. Check for continuity
and replace.
2. Coil winding opened.
2. Replace.
g) Compressor
1. Wiring to compressor.
1. Check for loose
connection or open, and
replace.
2. Defective.
2. Replace.
3. Protector tripped.
3. Reduce temperature.
h) Controller Board
1. Defective.
1. See "II.B.5. Checking
the Controller Board."
[4]
a) Water Solenoid Valve
1. Diaphragm does not
close.
1. Check for water leaks
with icemaker off.
b) Controller Board
1. Defective.
1. See "II.B.5. Checking
the Controller Board."
[5]
a) Water Supply Line
1. Water pressure too low
and water level in water
tank too low.
1. Check and get
recommended pressure.
b) Water Solenoid Valve
1. Dirty mesh filter or
orifice and water level in
water tank too low.
1. Clean.
c) Water System
1. Water leaks.
1. Check connections for
water leaks, and
replace.
2. Clogged.
2. Clean.
3. Pump out check valve
leaking by.
3. Check assembly and
clean.
Water continues to
be supplied in freeze
cycle.
No water comes from
spray tubes. Water
pump will not start, or
freeze cycle time is
too short.
Continued from
previous page.