57
7. WATER REGULATING VALVE - WATER-COOLED MODEL ONLY
[a] VALVE BODY
1) Unplug the icemaker or disconnect the power source.
2) Close the water supply tap.
3) Remove the front panel and right side panel.
4) Disconnect the flare connections of the water regulating valve.
5) Remove the valve from the bracket.
6) Install a new water regulating valve.
7) Connect the flare connections.
8) Open the water supply tap.
9) Check for water leaks.
10) Replace the panels in their correct positions.
11) Plug in the icemaker or connect the power source.
[b] WHOLE VALVE
IMPORTANT
Always install a new drier every time the sealed refrigeration system is
opened. Do not replace the drier until after all other repair or replacement
has been made.
1 Unplug the icemaker or disconnect the power source.
2) Close the water supply tap.
3) Remove the front, top and right side panels.
4) Recover the refrigerant and store it in a proper container, if required by an applicable
law (See “1. [b] REFRIGERANT RECOVERY”).
5) Cut off the copper tube near the capillary tube solder connection, using a pipe cutter.
Содержание IM-240ANE
Страница 4: ...1 I SPECIFICATIONS 1 DIMENSIONS SPECIFICATIONS a IM 240DNE Air cooled ...
Страница 5: ...2 b IM 240DNE C Air cooled ...
Страница 6: ...3 c IM 240DWNE Water cooled ...
Страница 7: ...4 d IM 240DWNE C Water cooled ...
Страница 8: ...5 e IM 240DWNE R452 Water cooled ...
Страница 9: ...6 f IM 240ANE Air cooled ...
Страница 10: ...7 g IM 240AWNE Water cooled ...
Страница 11: ...8 h IM 240DSNE Remote Air cooled ...
Страница 12: ...9 j URC 240C E 4 Condenser Unit ...
Страница 20: ...17 a CONTROLLER BOARD LAYOUT Main Board Sub Board Combination ...
Страница 37: ...34 2 WIRING DIAGRAM a IM 240DNE C XNE C IM 240DWNE C R452 XWNE C R452 IM 240ANE AWNE ...
Страница 38: ...35 b IM 240DSNE XSNE URC 240C E 4 ...
Страница 69: ...66 Fig 16 Controller Board Board Support Control Box Cover Screw ...