8
ENGLISH
Potable Water
Inlet G3/4
Inlet Hose
Drain Outlet R3/4
Outlet Hose
Cooling Water
Inlet Rc1/2
Cooling Water
Outlet Rc1/2
1/2-3/4 Nipple
Condenser Cooling Circuit
Model IM-30CW/45W: 295 - 760W
IM-65W:
875W
IM-100/130W:
1165W
IM-240W:
5235W
* Pipes between the cooling tower and the icemaker should be at least 20 mm DIA to reduce pressure loss, even though the
* Pressure loss in the water circuit inside the unit will be 5 to 6 m
* Select a circulating pump referring to the above values of heat
* Do not use a cascade pump, or the water regulator will vary the
[Icemaker Connections]
rubber sealing washer is correctly positioned. Hand tighten
2) Attach the other end of inlet hose to the water tap, noting
washer is correctly positioned before hand tightening as above.
only is on treated water supply, not the condenser.
can be cut to length as necessary to suit position of main drain.
4) By means of a suitable spanner or wrench, tighten the 1/2-3/4
nipples (accessory) into the Rc1/2 fittings on the rear of the
icemaker as indicated. P.T.F.E. tape and/or a suitable sealing
compound should be used to obtain a leak free joint.
Note: Jointing compounds should be approved and suitable for
potable water use.
5) Connect the condenser cooling circuit to the free end of 1/2-3/4
nipples as indicated using a suitable rigid type pipe.
1) Follow the instructions from 1) to 4) in [a] above.
2) For condenser connections, use supplied accessory hoses and make the same connections as 1) to 3) in [a] above to the free
end of 1/2-3/4 nipples as indicated.
Icemaker
Cooling
Tower
Flow Control Valve
Strainer
Pump
P