ENGLISH
13
[b] RAIL (customized)
* To attach the rail, (1) push the rail hook backwards
to fit into the square hole in the rear shelf post, and
(2) push the rail hook down to fit into the square
hole in the front shelf post. To detach the rail,
reverse the above procedure. See Fig. 9.
CAUTION
Attach the rail properly to make it level.
(1) Hook
(2) Hook
Fig. 9
(1)
(2)
[c] HANGER (customized)
6. ELECTRICAL CONNECTIONS
IMPORTANT
This refrigerator/freezer is provided with no
power switch or earth leakage circuit breaker,
but with overcurrent protection only. Install an
earth leakage circuit breaker with overload
protection rated at least 15A on the main
power supply.
* This refrigerator/freezer must be plugged into
the separated power receptacle which is readily
accessible and has enough capacity. The
maximum allowable voltage variation should not
exceed ± 10 percent of the nameplate rating. See
the nameplate.
* If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
7. DRAIN CONNECTIONS
CAUTION
Be sure to connect the drain hose properly.
Otherwise water leaks from the drain hose may
damage the surroundings (property).
IMPORTANT
1. Drain line shall be as short and straight
as possible. The drain hose shall have an
adequate pitch and fall so that no part is
higher than the drain outlet.
2. To prevent a backflow, do not connect the
drain hose directly with the sewer system.
An air gap of a minimum of 5 cm should be
between the end of the drain hose and the
water level of drainage.
Fig. 10
5 cm or more
Water Level