[f] SURGE ABSORBER
The Surge Absorber is provided to protect
the Controller Board from lightning.
[g] CAPACITOR - XY FILTER
The Capacitor - XY Filter is provided to
prevent the Controller Board from signal
errors caused by internal and external
noises.
[h] BIN CONTROL SWITCH
The Bin Control Switch is composed of a Proximity
Switch and Actuator. When the Chute fills up, ice will
push up the Actuator on top of the Chute to switch off
the Proximity Switch. After 7 seconds, the Controller
Board will stop the Gear Motor and Compressor at the
same time. When ice is used, the Actuator will return to
the original position to switch on the Proximity Switch.
The Gear Motor will restart in 7 seconds, and the
Compressor in 5 minutes.
When the Bin Control Switch seems to have
malfunctioned, check the dimensions of the Actuator
as well as the operation of the Proximity Switch. Also,
if the Chute Switch or the Gear Motor Circuit Protector
has operated for some unidentified reason, be sure to
check the Actuator for proper dimensions.
1) Remove the Bin Control Switch from the Chute.
2) Move the Actuator to the maximum operation angle
as shown below (top). Check that the Actuator is
about 13 mm away from the Barrier. If not, replace
the whole Bin Control Switch assembly.
Содержание FM-300AFE-HC
Страница 7: ...3 2 DIMENSIONS CONNECTIONS a FM 481AGE HC FM 481AGE HCN ...
Страница 8: ...4 b FM 300AFE HC FM 300AFE HCN ...
Страница 9: ...5 3 SPECIFICATIONS a FM 481AGE HC ...
Страница 10: ...6 b FM 481AGE HCN ...
Страница 11: ...7 c FM 300AFE HC ...
Страница 12: ...8 d FM 300AFE HCN ...
Страница 14: ...10 Drier Ice Chute Pressure Switch ...
Страница 23: ...19 b FM 300AFE HC FM 300AFE HCN Pressure Switch Cut out 22 6 1 5 0 bar Cut in 15 7 1 5 bar ...
Страница 24: ...20 2 WIRING DIAGRAM a WIRING DIAGRAM FM 481AGE HC FM 481AGE HCN ...
Страница 25: ...21 FM 300AFE HC FM 300AFE HCN ...
Страница 26: ...22 b CONTROL BOX LAYOUT FM 481AGE HC FM 481AGE HCN ...
Страница 27: ...23 FM 300AFE HC FM 300AFE HCN ...
Страница 35: ...31 FM 300AFE HC FM 300AFE HCN ...
Страница 36: ...32 ...
Страница 37: ...33 c SEQUENCE FM 481AGE HC FM 481AGE HCN 1 Startup Water Supply ...
Страница 38: ...34 FM 481AGE HC FM 481AGE HCN 2 Startup After completion of water supply Gear Motor and Fan Motor start 5 min ...
Страница 39: ...35 FM 481AGE HC FM 481AGE HCN 3 Startup Ice production starts ...
Страница 40: ...36 FM 481AGE HC FM 481AGE HCN 4 Normal Operation Bin Control ...
Страница 41: ...37 FM 481AGE HC FM 481AGE HCN 5 Shutdown Compressor stops 5 min ...
Страница 42: ...38 FM 481AGE HC FM 481AGE HCN 6 Shutdown Drain ...
Страница 43: ...39 FM 300AFE HC FM 300AFE HCN 1 Startup Water Supply ...
Страница 44: ...40 FM 300AFE HC FM 300AFE HCN 2 Startup After completion of water supply Gear Motor and Fan Motor start 5 min ...
Страница 45: ...41 FM 300AFE HC FM 300AFE HCN 3 Startup Ice production starts ...
Страница 46: ...42 FM 300AFE HC FM 300AFE HCN 4 Normal Operation Bin Control ...
Страница 47: ...43 FM 300AFE HC FM 300AFE HCN 5 Shutdown Compressor stops 5 min ...
Страница 48: ...44 FM 300AFE HC FM 300AFE HCN 6 Shutdown Drain ...