Hoshizaki FM-170EE-50-HC Скачать руководство пользователя страница 24

21

3) Replace the Front Panel (Left) and Top Panel in their correct position.

4) Open the water supply tap.

5) Connect the power supply and energise.

6) The following should occur in sequence:

a) Water Reservoir will fill.

b) Gear Motor will start.

c) Compressor will start.

IMPORTANT

1. Check the conditions and quality of the ice production.

2. Do not use ice produced in the trial run. It might be contaminated with 

foreign matter in the water circuit. Discard or flush down the drain.

3. Clean the Storage Bin before use (see “V. 1. PERIODICAL CLEANING”).

2. PREPARING THE ICEMAKER FOR LONG STORAGE

WARNING

When  shutting  off  the  icemaker  for  an  extended  time,  drain  out  all  water 

from the water line and remove ice from the Storage Bin. The Storage Bin 

should be cleaned and dried. Drain the icemaker to prevent damage to the 

water supply line at sub-freezing temperatures. Shut off the icemaker until 

the proper ambient temperature is resumed.

1) Close the water supply tap.

 

 

 

Fig. 8 

 

 

 

 

      Fig. 9

Circuit   

Motor   

  Operation

Breaker (6A)  Protector (3A)    Switch

Control Box

Front Panel

(Left)

Control Box

Condenser

Содержание FM-170EE-50-HC

Страница 1: ...NO E2EB 814 ISSUED AUG 21 2010 REVISED SERVICE MANUAL HOSHIZAKI MODULAR ICE MAKER MODEL FM 170EE HC FM 170EE HCN FM 170EE 50 HC FM 170EE 50 HCN...

Страница 2: ...NSTRUCTIONS 15 1 UNPACKING 15 2 LOCATION 16 3 INSTALLATION 17 4 ELECTRICAL CONNECTIONS 17 5 WATER SUPPLY AND DRAIN CONNECTIONS 19 IV OPERATING INSTRUCTIONS 20 1 START UP 20 2 PREPARING THE ICEMAKER FO...

Страница 3: ...TION CIRCUIT 38 a APPLICABLE PARTS 38 b SERVICE INSTRUCTIONS 38 c REFRIGERANT 38 d COMPRESSOR 39 e EVAPORATOR CASING 39 f CONDENSER 39 g CONDENSER COOLING FAN MOTOR 39 h DRIER 39 i THERMOSTATIC EXPANS...

Страница 4: ...1 I SPECIFICATIONS 1 DIMENSIONS CONNECTIONS a FM 170EE HC FM 170EE HCN...

Страница 5: ...2 b FM 170EE 50 HC FM 170EE 50 HCN...

Страница 6: ...3 2 SPECIFICATIONS a FM 170EE HC...

Страница 7: ...4 b FM 170EE HCN...

Страница 8: ...5 c FM 170EE 50 HC...

Страница 9: ...6 d FM 170EE 50 HCN...

Страница 10: ...E 50 HC and FM 170EE 50 HCN include Water Supply Evaporator Condensing and Control Assemblies Power Supply Cord Air Filter Top Panel Door Front Panel Left Front Cover Louver Spout Evaporator Reservoir...

Страница 11: ...8 ICE MAKING UNIT FM 170EE HC FM 170EE 50 HC...

Страница 12: ...9 ICE MAKING UNIT FM 170EE HCN FM 170EE 50 HCN...

Страница 13: ...cally commands the Water Valve to open and refill the Tank This system functions therefore to maintain a constant water level inside the Evaporator assembly The Auger which is located inside the Evapo...

Страница 14: ...ouch a metal part of the machine before servicing to be static free 3 Do not touch the electronic devices on either side of the board to prevent damage 4 Do not change wiring and connections Especiall...

Страница 15: ...12 c SEQUENCE Fig 1 Fig 2...

Страница 16: ...AA144C02 RATING 24 VAC 50 60Hz T1 60 15 sec T2 90 22 sec T3 150 45 sec T4 Max 1 sec T5 Max 0 25 sec T6 Max 1 sec CONTROL CTL PROTECT PRT X1 RELAY GEAR MOTOR X2 RELAY COMPRESSOR Note T time functions o...

Страница 17: ...X1 GM and X2 CM immediately When closed energize X1 GM in 1 sec and X2 CM in 60 sec 4 Terminals 7 8 9 X1 GM contacts 8 is a movable contact 7 is a make contact and 9 is a break contact 5 Terminals 10...

Страница 18: ...polystyrene as they are potential sources of danger CAUTION 1 Do not lift or manoeuvre the carton by using the shipping bands 2 Remove shipping carton tape s and packing If packing material is left in...

Страница 19: ...ard you Top Panel Remove the screws and lift up Fig 5 2 LOCATION WARNING 1 This icemaker is not intended for outdoor use Normal operating ambient temperature should be within 5 C to 40 C Normal operat...

Страница 20: ...igerant in its cooling unit maintenance and recharging must therefore only be carried out by authorized technicians 3 INSTALLATION Incorrect installation can cause harm to people animals or things for...

Страница 21: ...Yellow The wire which is coloured Blue must be connected to the terminal which is marked with the letter N or coloured Black The wire which is coloured Brown must be connected to the terminal which i...

Страница 22: ...w so ensure drain pipe has an adequate pitch or fall Water should drain into an open trap 1 Attach angled end of white flexible inlet hose accessory to the G3 4 fitting at the top rear of the icemaker...

Страница 23: ...f in doubt disconnect the icemaker Do not damage the power cord or pull it in order to disconnect the icemaker from the feed network Use the attachment plug as the main power disconnect switch for the...

Страница 24: ...cuit Discard or flush down the drain 3 Clean the Storage Bin before use see V 1 PERIODICAL CLEANING 2 PREPARING THE ICEMAKER FOR LONG STORAGE WARNING When shutting off the icemaker for an extended tim...

Страница 25: ...from the electrical supply network 2 A trained service person should check and clean the Condenser at least once a year 3 This appliance must not be cleaned by use of a water jet 4 To prevent possible...

Страница 26: ...commended Hoshizaki sanitiser as directed 2 Soak the Scoop in the solution for more than 3 minutes Rinse thoroughly and shake to remove surplus liquid Note Using a cloth to dry may re contaminate 3 Us...

Страница 27: ...attempt to shorten cleaning time 5 Wipe off any splashed or spilt cleaner sanitiser immediately 6 Do not use any ammonia type cleaners on any part of the icemaker STEP 1 Dilute the solutions with wat...

Страница 28: ...Panel and refit the Front Panel Left in position 12 Allow the icemaker to stand for about 10 minutes then plug in the icemaker to make ice with the solution until the machine automatically stops 13 O...

Страница 29: ...tap 22 Follow items 4 to 20 to complete sanitisation of the water system STEP 4 Use the remaining sanitising solution to sanitise removable parts 23 Remove the Front Panel Left and lift off the Top P...

Страница 30: ...ng a brush Rinse with fresh water 33 Refit the Mesh into the Valve and the Valve into its correct position 34 Open the water supply tap and check for leaks 35 Refit the Top and Front Panels securely w...

Страница 31: ...28 VI TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERANT CIRCUIT...

Страница 32: ...29 2 WIRING DIAGRAM...

Страница 33: ...automatically reset to resume normal operation b PROTECTORS 1 Pressure Switch If the Pressure Switch activates the Gear Motor Fan Motor and Compressor stop simultaneously in 0 25 sec When the switch r...

Страница 34: ...N OFF ON OFF ON OFF ON OFF 1sec 0 25sec 1sec 60sec 60sec PRESSURE SWITCH MOTOR PROTECTOR POWER ON OFF RESET ON OFF 3 Low Water Control The icemaker will stop when the water level in the Reservoir fall...

Страница 35: ...60 465 470 475 480 485 490 495 500 10 10 21 15 32 21 Ambient Temp Water Temp C Electric Consumption KWH day 0 2 4 6 8 10 12 14 16 18 10 10 21 15 32 21 Ambient Temp Water Temp C Head Pressure bar 0 0 5...

Страница 36: ...p C Ice Production Capacity kg day 470 475 480 485 490 495 500 505 10 10 21 15 32 21 Ambient Temp Water Temp C Electric Consumption KWH day 0 2 4 6 8 10 12 14 16 18 10 10 21 15 32 21 Ambient Temp Wate...

Страница 37: ...contacts 1 Check for continuity and replace h Bin Control 2 Activator does not move freely 2 Clean Axle and its corresponding holes or replace Bin Control 1 Bin Control defective 1 Check Bin Control a...

Страница 38: ...place Timer 1 Bad contacts 1 Check for continuity and replace 2 Coil winding opened 2 Replace b Starter 3 Loose connections 3 Tighten c Start Capacitor or Run Capacitor 1 Defective 1 Replace 1 Loose c...

Страница 39: ...sary 3 OTHERS PROBLEM CHECK POSSIBLE CAUSE REMEDY 1 Bearing worn out 1 Replace 2 Fan blade deformed 2 Replace fan blade a Fan Motor 3 Fan blade does not move freely 3 Replace 1 Bearings worn out or cy...

Страница 40: ...or too low 1 Connect the unit to a power supply of proper voltage b Evaporator Assy 1 Bearings or Auger worn out 1 Replace Bearing or Auger 3 Gear Motor Protector operates frequently c Bin Control 1 A...

Страница 41: ...INSTRUCTIONS Always restore the original bindings after servicing the refrigeration circuit Otherwise vibration may cause overstress and damage to the circuit resulting in refrigerant leak After repla...

Страница 42: ...vaporator Casing is deprived of heat and forms ice film which will be scraped and moved up by the Auger f CONDENSER The Condenser refrigerates and liquefies the high temperature high pressure refriger...

Страница 43: ...Expansion Valve for proper operation remove the Bulb while the Compressor is running If the suction pressure rises the Expansion Valve is working normally Note Do not leave the Bulb removed for a long...

Страница 44: ...r Extruding Head Auger Ring Mechanical Seal Evaporator O ring Lower Bearing Coupling Spline Gear Motor Socket Head Cap Screw Socket Head Cap Screw with Washer FM 170EE HC FM 170EE 50 HC FM 170EE HCN F...

Страница 45: ...ker 4 FLOAT SWITCH 1 Unplug the icemaker 2 Close the water supply tap 3 Remove the Inlet Hose from the water tap and drain the Hose 4 Remove the Top Panel and the Front Panel Left 5 Drain the water sy...

Страница 46: ...6 Loosen the Fitting Nut on the Control Water Valve Inlet and remove the Control Water Valve Do not lose the Packing inside the Fitting Nut 7 Remove the Reservoir Inlet Cover from the Control Water Va...