Functions of Terminals
1) Terminals 1, 2
Power supply AC 24V.
2) Terminals 3, 4
Control X
1
(GM) and X
2
(CM) Relays.
When closed, energize X
1
(GM) in 1 sec. and X
2
(CM) in 60 sec.
When opened, de-energize X
1
(GM) in 150 sec. and X
2
(CM) in 90 sec.
3) Terminals 5, 6
Control X
1
(GM) and X
2
(CM) Relays.
When opened, de-energize X
1
(GM) and X
2
(CM) immediately.
When closed, energize X
1
(GM) in 1 sec. and X
2
(CM) in 60 sec.
4) Terminals 7, 8, 9
X
1
(GM) contacts.
8 is a movable contact, 7 is a make contact, and 9 is a break contact.
5) Terminals 10, 11
Control X
2
(CM) Relay.
When opened, de-energize X
2
(CM) immediately.
When closed, energize X
2
(CM) immediately.
Note: 1. X
2
Relay is a single pole, normally open relay, and its terminals are mounted on
the relay itself.
2. The above operation times are median. See Fig. 3 for details.
3. GM = Gear Motor
CM = Compressor
Содержание FM-170EE-50-HC
Страница 4: ...1 I SPECIFICATIONS 1 DIMENSIONS CONNECTIONS a FM 170EE HC FM 170EE HCN...
Страница 5: ...2 b FM 170EE 50 HC FM 170EE 50 HCN...
Страница 6: ...3 2 SPECIFICATIONS a FM 170EE HC...
Страница 7: ...4 b FM 170EE HCN...
Страница 8: ...5 c FM 170EE 50 HC...
Страница 9: ...6 d FM 170EE 50 HCN...
Страница 11: ...8 ICE MAKING UNIT FM 170EE HC FM 170EE 50 HC...
Страница 12: ...9 ICE MAKING UNIT FM 170EE HCN FM 170EE 50 HCN...
Страница 15: ...12 c SEQUENCE Fig 1 Fig 2...
Страница 31: ...28 VI TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERANT CIRCUIT...
Страница 32: ...29 2 WIRING DIAGRAM...