Above 300 μS/cm:

Excessive ice may build up on evaporator and freeze beer inside beer coil preventing beer from being dispensed properly.

How to make cooling water with 100-300 μS/cm of E.C.

The capacity of the water tank of this unit is approx. 30 L.

Make the cooling water by dissolving 5 g of pure baking soda in approx. 10 L of distilled water, 

and then add approx. 27 L of distilled water to fill the water tank.

Step 1

Measure 5 g of pure baking soda with nozzle cap (accessory).

Step 2

Fill a bucket with approx. 10 L of distilled water and stir well after adding the 5 g of baking 

soda measured in step 1.

Rinse the nozzle cap after use.

[b] COOLING WATER SUPPLY

WARNING

Before filling the water tank, turn off the power switch (earth leakage breaker) and unplug the unit.

NOTICE

Do not splash water on the electrical parts.

Do not fill the water tank above the water level line, or the drain pan will overflow and spill water.

1) Remove the top cover.

2) Pour the bucket (approx. 10 L) of cooling water prepared.

3) Fill the water tank up with approx. 27 L of distilled water to the water level line marked inside 

the water tank.

4) Use a conductivity meter if measuring the electric conductivity.

5) Close the top cover.

3. CHECKS BEFORE OPERATION (DAILY)

[a] CHECKING CO2 GAS CYLINDER

Open the main valve of the CO2 gas cylinder, and check the gas 

pressure by the level gauge of the regulator:

* If the level gauge reading is not more than 3 MPa or falls into the 

yellow zone, the cylinder contains little CO2 gas.

* If the level gauge reading is not more than 1 MPa or falls into the 

red zone, replace with a new cylinder.

[b] REPLACING CO2 GAS CYLINDER

1) Close the main valve of the CO2 gas cylinder by turning it clockwise.

2) Turn the regulator adjust dial to set the pressure to “0” (MPa).

3) Use the spanner (accessory) to loosen the nut and remove the regulator from the CO2 gas 

cylinder.

Note:  Be sure to cap the CO2 gas cylinder.

4) Open the main valve of the new CO2 gas cylinder for a second to blow dirt and dust off the 

joint (together with CO2 gas).

Level Gauge

Nut

Main Valve

Regulator

Adjust Dial

Gasket

CO2 Gas Cylinder

* The regulator design is different 

for each beer company.

Cap

Distilled Water

(approx. 10 L)

Bucket

Nozzle Cap 5/6 

(5 g)

Nozzle Cap

Water Tank

中文:478537L01

Содержание DBF-AS65WE-T

Страница 1: ...DBF AS65WE T L1B078101 103119 AUTOMATIC DRAFT BEER DISPENSER INSTRUCTION MANUAL 3 16 Minamiyakata Sakae cho Toyoake Aichi 470 1194 Japan...

Страница 2: ...15 5 SETTING LIQUID AND FOAM AMOUNTS 16 a LARGER MUG SETTING 16 b SMALLER MUG SETTING 16 6 DISPENSING 17 a AUTOMATIC DISPENSING 17 b STOPPING AUTOMATIC DISPENSING 17 c MANUAL DISPENSING 17 d SWITCHIN...

Страница 3: ...ous The manufacturer will not be held liable or responsible for any damage caused by improper incorrect and unreasonable use The installation and relocation if necessary must be carried out by qualifi...

Страница 4: ...ode Stop Button Press once Manually stops the beer tap or platform operation Press and hold Resets the display indication e g number of mugs Foam Button In ready mode Press and hold to dispense foam I...

Страница 5: ...er Hose Adapter 2 O Ring S P10A 2 Spanner 1 Hook 1 Hook Mounting Screw 2 Cylinder Chain 1 O Ring L P21 1 Grille 1 Platform 2 3 UNPACKING WARNING Children should not be allowed in reach of the packagin...

Страница 6: ...level foundation for the dispenser NOTICE Do not place anything to obstruct the ventilation louvers IMPORTANT Normal operating ambient temperature should be within 5 C to 32 C cooling water temperatu...

Страница 7: ...g Distance A 274 mm Distance B 388 mm After Adjustment Distance a 244 mm Distance b 328 mm b DRAIN PAN To attach the drain pan accessory and grille accessory 1 lift up the front of the drain pan 2 pus...

Страница 8: ...d 12th levels The top of the mug must fit the mark on the back plate when positioned on the platform See the table on the next page for the mug heights and platform positions 3 After adjusting the pla...

Страница 9: ...175 Upper 190 Upper 180 7 Lower 195 Lower 185 Upper 200 Upper 190 8 Not available Lower 195 Upper 200 9 Lower 205 Upper 210 10 Lower 215 Upper 220 11 Lower 225 Upper 230 12 Lower 235 Upper 240 Note 1...

Страница 10: ...an undamaged gasket to prevent the risk of gas leaks If not contact the liquor shop beer company or distributor to install a new gasket Stand the CO2 gas cylinder upright and fix it securely with the...

Страница 11: ...connect the CO2 gas hose push it all the way in 2 To disconnect the CO2 gas hose push and hold part 1 with fingers and pull out the hose 2 Beer Hose 1 Attach the O ring S P10A accessory to the smaller...

Страница 12: ...ottom 8 Pull the beer tap lever toward you to pour water out of the liquid nozzle 9 Check the CO2 gas circuit for gas leaks If it is leaking correct the hose connections 10 Check the beer circuit for...

Страница 13: ...formed for more than 1 minute the dispensing mode is resumed In that case go back to step 2 above 10 USER SETTINGS To make or change settings Press and hold the set button for 3 seconds to enter the s...

Страница 14: ...ense button 0 0 1 U09 Mug tilting operation 0 Yes mug is tilted while beer is being dispensed 1 No mug is kept upright while beer is being dispensed 0 0 1 U10 Reset number of mugs 0 Manual 1 Manual or...

Страница 15: ...water tank up with approx 27 L of distilled water to the water level line marked inside the water tank 4 Use a conductivity meter if measuring the electric conductivity 5 Close the top cover 3 CHECKS...

Страница 16: ...of CO2 gas from beer The higher the beer keg temperature is the easier the CO2 gas separates and a higher gas pressure is required Beer Keg Temperature Gas Pressure Note The values are for reference o...

Страница 17: ...ontact your dealer supplier To prevent electric shock or fire do not turn it back on In case of trouble unplug the unit or disconnect the main power supply and immediately contact your dealer supplier...

Страница 18: ...y vary depending on the performance of the regulator controlling the CO2 gas pressure If the set amounts vary too much the regulator must be replaced Empty the drain pan frequently before it overflows...

Страница 19: ...tact your dealer supplier To stop the automatic dispensing operation halfway through 1 Press the stop button The platform stops at that position When the stop button is pressed again the platform goes...

Страница 20: ...is factory set to 0 Setting A mainly beer In the manual dispensing mode the unit will not stop dispensing even if the sold out lamp lights up Be careful with the keg level while dispensing beer When...

Страница 21: ...After draining the water tank remove the top cover to dry the water tank interior III MAINTENANCE WARNING Before carrying out any cleaning or maintenance operations unplug the dispenser from the elect...

Страница 22: ...Vertical type Unlock and lift the keg coupler handle all the way up 3 Turn the regulator adjust dial to set the pressure to 0 MPa 4 Close the main valve of the CO2 gas cylinder by turning it clockwise...

Страница 23: ...op button to close the beer tap 18 Close the beer circuit Rotary type Turn the keg coupler handle counterclockwise until it stops Vertical type Unlock and lift the keg coupler handle all the way up 19...

Страница 24: ...KLY To flush the beer circuit use the cleaning tank specified by the beer company Follow the instructions provided with the cleaning tank 1 Follow the steps of 2 BEER CIRCUIT 2 Lift up the operation p...

Страница 25: ...to set the pressure to 0 15 MPa 15 Open the beer circuit Rotary type Turn the keg coupler handle clockwise until it stops Vertical type Push down the keg coupler handle until it locks in place Note I...

Страница 26: ...nt handle toward you to unlock Pull down the operation panel unit until it stops to cover up the beer tap lever Note To prevent malfunction do not pull down the operation panel unit with the beer tap...

Страница 27: ...8 EXTERIOR WEEKLY The exterior is easily contaminated Always keep it clean NOTICE To prevent damage do not use any cleaner other than a neutral cleaner on the plastic exterior 1 Wipe with a cloth con...

Страница 28: ...e gas and beer hoses for damage deformation and water leak marks stains If any problem is found contact your dealer supplier 3 ATTACHMENT PLUG AND POWER CORD ANNUALLY BIANNUALLY WARNING Check periodic...

Страница 29: ...blown out Contact your dealer supplier Power failure Wait until power is resumed Beer is not cold No ice in the water tank Wait until ice is produced Less than 8 to 13 hours after the power switch ea...

Страница 30: ...at the time of setting Too little or too much liquid or foam The regulator adjust dial has been turned after liquid amount adjustment Readjust the CO2 gas pressure and the liquid and foam amounts Sol...

Страница 31: ...A Electric Consumption Motor 285 345W Ice Making Time 10 hrs ambient temp 30 C initial cooling water temp 25 C Dispensing Capacity 65 L 30 C to 8 C 4 hrs Dimensions 367mm W x 674mm D x 764mm H Refrige...

Отзывы: