12
ENGLISH
U04
Number of keg
replacements
(reset frequency)
Reset frequency for number of mugs
* Keg replacement is counted every time the number of kegs is reset by the
stop button operation.
* To reset, press and hold the stop button for 3 seconds.
0
0 - 9999
U05 Dispense lamp
brightness
Adjustment of dispense lamp brightness
6
1 - 8
U06
Dispense lamp flashing
duration
Adjustment of dispense lamp flashing duration after completion of
dispensing
* The dispense lamp flashes to prevent another mug is placed while foam is
still dripping.
* Automatic dispensing action is not available while the lamp is flashing.
1
0 - 10
U07 Sold out sensor setting
0: Setting A (mainly beer) / threshold: 2.2V
1: Setting B (mainly cocktail) / threshold: 2.5V
2: Setting C (mainly cocktail) / threshold: 2.8V
3: Setting D (optional) / threshold: optional
* The setting depends on the brand of beverage to dispense. Check with your
dealer/supplier.
0
0 - 3
U08 Self mode setting
0: No
1: Yes (no button operation is available except dispense/stop button)
* The self mode is reset when the manual dispensing mode is selected (by
lifting up the operation panel unit). To resume the self mode, switch to the
automatic dispensing mode (by pulling down the operation panel unit) and
press the dispense button.
0
0 - 1
U09 Mug tilting operation
0: Yes (mug is tilted while beer is being dispensed)
1: No (mug is kept upright while beer is being dispensed)
0
0 - 1
U10 Reset number of mugs
0: Manual
1: Manual or when sold out sensor detects
* To reset manually, press and hold the stop button for 3 seconds.
0
0 - 1
U90 Reset settings
Initialize only the user settings
* To initialize, with “1” shown on the display, press and hold the stop button
for 3 seconds.
* If the settings are updated, “U90” appears on the display. If not updated, “0”
appears again.
0
0 - 1
II. OPERATING INSTRUCTIONS
1. CLEANING BEER CIRCUIT
Although the beer circuit is cleaned before shipping, clean it again before use. See “III. 2. BEER CIRCUIT”.
Check that the parts are installed in their correct positions. See “I. 1. CONSTRUCTION”.
2. FILLING WATER TANK
NOTICE
Use only the specified water to fill the water tank. Use of any other water or mixture of salt, vinegar or juice may cause insufficient
ice storage, corrosion or perforation.
[a] HOW TO MAKE COOLING WATER
IMPORTANT
Carefully read this before filling the water tank.
Electric conductivity (E.C.) of cooling water for water tank
Do not use tap water.
Fill the water tank with water having 100-300 μS/cm of E.C.
Measure the electric conductivity with conductivity meter.
* E.C. : Physical property to show the ability of conducting electricity.
Unit: μS(microsiemens)/cm
Below 100 μS/cm:
Compressor may not work resulting in poor cooling performance.