HOSHIZAKI EUROPE B.V.
d22
Evap temperature for d18
2
2
2
2
A1
Min. room temperature alarm
10
10
10
10
A4
Max. room temperature alarm
10
10
10
10
A6
Dly max room temp. Alrm aft swit.
on
99
99
99
99
A7
Delay min max temp
120
120
120
120
A8
Dly max temp alrm aftr evap fan
stnstll
120
120
120
120
A9
Dly max temp alrm aftr door swt
input
30
30
30
30
A11
Differential of A1 and A4
1
1
1
1
F0
Evap fan activity
3
3
3
3
F1
Evap fan switch off above temp
8
8
8
8
F2
Evap fan activity during defr. and
drip
1
1
0
0
F3
Evap fan deactvtion after comp
swt on
2
2
2
2
F4
Evap fan swt off during enrgy save
fnc
30
30
30
30
F5
Evap fan swt on during enrgy save
fnc
30
30
30
30
ı0
Evap fan or comp activton by door
swt
2
2
2
2
ı1
Door switch activity type
1
1
1
1
ı2
Door switch alarm activity and
delay
2
2
2
2
ı3
Door switch activity time
10
10
10
10
ı10
Door swit activity and abot enrgy
sving
0
0
0
0
ı13
Numbr of door swt act for defrost
0
0
0
0
ı14
Min duration of door swt for
defrost
0
0
0
0
u0
2nd relay management
1
1
1
1
u2
aux input manuel activated
1
1
1
1
u4
door resistances start time
1
1
1
1
HE2
Max duration for energy saving
0
0
0
0
HE3
Energy saving func activation
0
0
0
0
POF
Key activation
1
1
1
1
PAS
Access to password
-19
-19
-19
-19
18
Содержание 877000901
Страница 1: ...HOSHIZAKI EUROPE B V SERVICE MANUAL HOSHIZAKI SNOWFLAKE GII SUR 65EG SUF 65EG SUR 135EG SUF 135EG 1...
Страница 26: ...HOSHIZAKI EUROPE B V SUR 65EG SUF 65EG 26 Dimensions...
Страница 27: ...HOSHIZAKI EUROPE B V SUR 65EG SUF 65EG 27 Dimensions...
Страница 28: ...HOSHIZAKI EUROPE B V 28 Wiring diagram...
Страница 29: ...HOSHIZAKI EUROPE B V 29 Wiring diagram...
Страница 31: ...HOSHIZAKI EUROPE B V 31 EU Declaration of Conformity SUR SUF EG...
Страница 32: ...HOSHIZAKI EUROPE B V 32 UKCA Declaration of Conformity SUR SUF EG...