HOSHIZAKI EUROPE B.V.
If required, the keypad can be unlocked by pressing any key for 4
seconds; “UnL” is displayed.
Briefly press the key
; the compressor indicator
flashes and the temperature set point is
displayed. By briefly pressing
or
again, or after 15 seconds without pressing
any keys, the device returns to normal operation.
If required, the keypad can be unlocked by pressing any key for 4
seconds; “UnL” is displayed.
Briefly press the key
; the compressor indicator
flashes and the temperature set point is
displayed; it can be changed via
or
. Press
to save the value and leave the
parameter. You can leave and discard the change (escape) by pressing
.
You switch on the cabinet by pressing the ON/OFF button
for approximately 4 seconds.
flashes while it is being switched off. In standby mode,
is constantly lit.
Indicator
Description
AL
Lower temperature
alarm, parameter “A1”, delay “A7”
AH
Upper temperature
alarm, parameter “A4”, delay “A7”
dEF
Device is undergoing the defrost process (if
“D6”=“2”) or a reset to default factory settings
Id
Door
alarm, parameter “Id”, parameter “i0”, “i1”
Pr1
Defective room sensor, emergency programme
parameter “C4”, “C5”
Pr2
Defective evaporator sensor, defrosting after time period
“d3”
14
Alarm and fault messages, display of the defrosting process
Switching off the device in standby mode:
Temperature setting (changing the set point)
Display of set temperature (set point)
Содержание 877000901
Страница 1: ...HOSHIZAKI EUROPE B V SERVICE MANUAL HOSHIZAKI SNOWFLAKE GII SUR 65EG SUF 65EG SUR 135EG SUF 135EG 1...
Страница 26: ...HOSHIZAKI EUROPE B V SUR 65EG SUF 65EG 26 Dimensions...
Страница 27: ...HOSHIZAKI EUROPE B V SUR 65EG SUF 65EG 27 Dimensions...
Страница 28: ...HOSHIZAKI EUROPE B V 28 Wiring diagram...
Страница 29: ...HOSHIZAKI EUROPE B V 29 Wiring diagram...
Страница 31: ...HOSHIZAKI EUROPE B V 31 EU Declaration of Conformity SUR SUF EG...
Страница 32: ...HOSHIZAKI EUROPE B V 32 UKCA Declaration of Conformity SUR SUF EG...