background image

4

Wiring Box Mounting

The C-Stat wall plate may be fitted directly on to a single gang 
steel flush wiring box complying with BS4662, using two M3.5 
screws. The C-stat is suitable for mounting on a flat surface only; 
it must not be positioned on an unearthed metal surface.

Electrical Connections

All necessary electrical connections should now be made. Flush 
wiring can enter from the rear through the aperture in the wall 
plate. 

A Pattress is supplied to allow mains surface wiring to enter the 
unit.

The mains supply terminals are intended to be connected to the 
supply by means of fixed wiring.

The C-Stat is mains powered and requires a 3 Amp fused spur. 
The recommended cable size is 1.0mm².

The C-Stat is double insulated and does not require an earth 
connection,  an  earth  connection  block  is  provided  on  the 
backplate  for  terminating  any  cable  earth  conductors.  Earth 
continuity  must  be  maintained  and  all  bare  earth  conductors 
must be sleeved. Ensure that no conductors are left protruding 
outside the central space enclosed by the backplate.

Содержание C-Stat 11-M

Страница 1: ... intuitive user interface making them easy to set up and use C Stat uses a sophisticated time proportional integral TPI algorithm for accurate temperature control and energy efficiency Being mains powered these models won t need the batteries changing every two years Installation and connection should only be carried out by a suitable qualified person and in accordance with the edition of the IEE ...

Страница 2: ...be mounted on an internal wall approximately 1 5 metres from floor level and should be in a position away from draughts direct heat and sunlight Ensure that there will be enough space to allow access to the two retaining screws located at the base of the wall plate 2 1 5m ...

Страница 3: ...nt damage from dust debris etc The wall plate should be fitted in a position which allows a total clearance of at least 50mm around the C Stat programmable thermostat Direct Wall Mounting Offer the plate to the wall in the position the C Stat is to be mounted and mark the fixing positions through the slots in the wall plate Drill and plug the wall then secure the plate in position The slots in the...

Страница 4: ... plate A Pattress is supplied to allow mains surface wiring to enter the unit The mains supply terminals are intended to be connected to the supply by means of fixed wiring The C Stat is mains powered and requires a 3 Amp fused spur The recommended cable size is 1 0mm The C Stat is double insulated and does not require an earth connection an earth connection block is provided on the backplate for ...

Страница 5: ... ensure that all wiring complies with current IEE regulations ŸThe C Stat have voltage free contacts ŸFor mains voltage switching applications link terminal L 1 ŸFor low voltage switching applications apply low voltage to terminal 1 with no links 5 CALL 1 2 3 4 L N 230V MAINS SUPPLY CALL FOR HEAT ...

Страница 6: ...L Mains Supply COOLING LOAD C Stat C Stat conjunction with a contactor wired to control a cooling load When necessary the should be used in N L ON OFF ON OFF HOT WATER CENTRAL HEATING PUMP BOILER Programmer MAINS SUPPLY MAINS SUPPLY N L E N L E N L ROOM STAT ROOM STAT SAT CALL SAT CALL CYL STAT C C N C Stat programmer and two spring return valves with auxiliary switches controlling a secondary hea...

Страница 7: ...Stat MAINS SUPPLY N L E CALL SAT CALL CYL STAT C SAT 1 3 4 PUMP BOILER N L C Stat replacing a conventional room thermostat on a fully pumped system with an existing programmer and two spring return valves with auxiliary switches C Stat replacing a conventional room thermostat on a fully pumped system with an existing programmer and 3 port mid position valve L N 230V MAINS SUPPLY L N 230V MAINS SUP...

Страница 8: ...ly operated thermostats As a consequence a TPI regulating thermostat will maintain the comfort level far more efficiently than any traditional thermostat When used with a condensing boiler the TPI thermostat will help to save energy as the control algorithm allows the boiler to operate in condensing mode more consistently compared to older types of thermostat ŸFor Gas boilers ser the TPI setting t...

Страница 9: ... top of the wall plate before pushing it firmly home into its plug in terminal block Tighten the 2 captive screws on the underside of the unit Now ensure that the heating system is responding to the On Off commands from the C Stat Explain its operation to the householder and hand over the users operating instructions to the user ...

Страница 10: ...lock display Default setting Daylight saving On or Off Default setting ON for UK Market Standby temperature Frost protection setting Default setting 5 C Upper and Lower Default settings 30 C and 5 C Temperature limits TPI Cycles This setting will change according to the type of boiler being used Default setting 6 For Gas boiler this setting should be 6 cycles per hour For Oil boilers this setting ...

Страница 11: ... the thermostat Electronic equipment can in some circumstances be affected by electrical interference If the display becomes frozen or scrambled simply press both the BACK and ENTER button simultaneously BACK ENTER ...

Страница 12: ...e free c o contacts SPDT Contact voltage rating 230V ac 50Hz 30V dc Contact current rating 8A 1Ainductive Temperature differential 0 5 C Temperature accuracy 0 5 C to 21 C Impulse rating Category II 2500 V Standards BS EN 60730 2 9 Dimensions WxHxD 120mm x 100mm x 26 5mm Weight 0 3kg approx Enclosure Flame retardant thermoplastic Ingress protection IP30 Pollution degree Degree 2 Insulation class C...

Отзывы: