Seed flow diagnose
The seed flow diagnose indicates the blocked
sensors, but also defective sensors or broken
cables.
In the first line the "CAN-Frames" and in the sec-
ond line the status is counted. As long as these
continue to count the monitoring is functioning.
At "E" the type of fault is displayed, a cable
breakage with "1" and any other fault with "9".
At "S" the last functioning sensor is indicated.
The fault or broken cable must be located after
this sensor.
The bottom section shows the operating status
of each sensor. The figure 1 represents each
sensor without fault. Blocked sensors are indi-
cated with "0".
After correcting a fault it will take up to 1 minute
until the current operating status is displayed
again.
Alarm message
In case of blockage or quantity deviations the
message "No seed flow at sensor XX" will be
displayed.
If several hoses are blocked only the first number
of the clogged hoses will be indicated in the
alarm.
The other numbers of clogged hoses are dis-
played on the third work page.
Key (4) can be used to switch into the seed flow
system for trouble shooting.
4
No
seed flow
Sensor 3