![Hornell Adflo Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/hornell/adflo/adflo_instruction-manual_2163900018.webp)
Appendix A
Definition of Safety Signal Words per
ANSI Z535.4
indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury. It may
also be used to alert against unsafe practices.
93-0061-00 Rev. A
18
Adflo
®
Turbo Unit
Appendix B
Technical Specifications for Adflo
®
Turbo
Unit Powered Air Purifier:
Assigned Protection Factor
(for approved purifier/
headpiece combination):
25
Airflow:
6+ cfm (170+ lpm)
Noise:
<70 db at maximum
airflow
Weight, Adflo
®
unit with
battery, belt, breathing tube: 4.48 lbs (2.03 kg)
Weight, OV/SD/CL/HC
Adflo
®
Cartridge:
1.62 lbs (0.74 kg)
Operating Temperatures:
23° to 131°F
(-5° to 55°C)
Respirator Approval:
refer to the (NIOSH 42
CFR 84) Respirator
Approval Label for all
approved purifier/
headpiece combinations.
Battery Life:
Approximately 520
charges
Belt Size:
75-115 cm
!
CAUTION
!
WARNING