Adflo
®
Turbo Unit
The Adflo
®
Turbo Unit must be stored in a dry, clean
area, in the temperature range of -4°F to +131°F (-20°C
to +55°C) and relative humidity of less than 90%RH.
The Adflo
®
Turbo Unit can withstand brief periods of
storage at +185°F (+85°C).
If the Adflo
®
Turbo Unit is stored at temperatures
below 32°F (0°C), the battery pack must be allowed to
warm up to achieve optimal battery performance. The
Adflo
®
Turbo Unit must be protected from dust,
particles, and other contamination when stored between
use, in a clean environment, in the Carry Bag.
3.2 Removing & Reinstalling the Battery
Pack
Hold the Adflo
®
Turbo Unit so the “Adflo
®
” logo faces
you; press in on the battery pack catch found
immediately to the right of the logo (see Figure 9A)
and lift out the battery.
To reinstall, hook the left edge of the battery pack into
its holder and then press the right side of the battery
until the catch fully engages (see Figure 9B).
3.1 Cleaning & Storage
The outer surfaces of the Adflo
®
Turbo Unit may be
cleaned with a soft cloth dampened in a mild solution
of clean water and mild detergent. Abrasive cleaners
or solvents must not be used.
Detach the breathing tube from the Adflo
®
Turbo Unit
and inspect for holes or tears. Wipe clean the
connection sites on the Adflo
®
Turbo Unit and the
headpiece assembly. If you suspect that the inside of
the breathing tube is dirty, it must be replaced with
a new breathing tube (see Chapter 4).
Chapter 3 System Maintenance
!
WARNING
Do not allow contaminant to enter
into the breathing tube or Adflo
®
Turbo Unit. Failure to prevent con-
taminant from entering into the
breathing tube or Adflo
®
Turbo Unit
could lead to contaminant expo-
sure resulting in serious bodily
injury or loss of life. Consult your
local safety professional in the
event contaminant entry into the
breathing tube or Adflo
®
Turbo Unit
is suspected.
Do not allow water to enter into the
Adflo
®
Turbo Unit or the battery
pack. Failure to prevent water from
entering into the Adflo
®
Turbo Unit
or the battery pack could cause
product failure leading to contami-
nant exposure resulting in serious
bodily injury or loss of life. Any fil-
ters or cartridges which have been
directly exposed to water must be
disposed of in accordance with
state, local and federal ordinances.
Do not clean any part of the system
with gasoline, organic-based sol-
vents, or chlorinated degreasing
fluids (such as trichloroethylene).
Failure to prevent cleaning with
any of these substances could lead
to contaminant exposure and/or
product failure resulting in serious
bodily injury or loss of life.
Figure 9:
Removing & Reinstalling the Battery Pack.
9A
9B