For more information visit:
www.hornby.com
The
Hornby Select Digital Control
unit can have stored in its memory 59 digitally controlled locomotives.
At any one time the
Select
can have running (providing the power is available) or on standby 10 locomotives.
This is more than sufficient for an above average layout, however should an eleventh loco be “called up”, one of
the previous 10 locomotives will be returned to the memory. The locomotive that is returned, will be the
locomotive that has the lowest current Speed address compared to the other 9.
Alternatively, if all 10 locomotives are stationary, the locomotive with the lowest address number will be returned
to the memory.
Control Up to 10 Locomotives
The transformer included with the
Select
unit will probably provide enough power to allow for three locomotives
to be running at any one time, providing the models used are fitted with power efficient motors. Should more
power be needed the
Select
unit is capable of being connected to a R 8113 Hornby 4 amp Power Unit which
should provide enough power for an average layout.
If under special circumstances even more power is needed it may become necessary for a “Booster” unit to be
fitted.This will entail the track circuit to be broken up into large isolating sections to which the Booster is connected.
The Booster will in turn be connected to the XpressNet port at the back of the Select unit.
There are several “Boosters” on the market, with each one supplied complete with the relevant fitting
instructions.
Consult your Hornby DCC dealer for further details and advice.
15V DC Analogue Accessory Power Supply
The
Hornby Select Digital Control
unit incorporates a separate 15V DC outlet which can be used to power
non-digital controlled accessories (analogue) such as point motors or similar devices as well as lighting.
Power Boosters
18
19
Re-setting the Control Unit
Re-setting the
Hornby Digital Control Unit
will remove all previously assigned addresses from the units
memory (with the exception of No. 3). Groups created for Double Heading will also be cleared from the units
memory.
RESETTING THE CONTROL UNIT DOES NOT REMOVE ADDRESSES FROM LOCOMOTIVES.
To perform a reset:
1.
Press and hold the STOP
+
.The LCD display will display “C5” (Command Station).
2.
Press Select.The LCD will display “0”.
3.
Press Select.The red LED will flash 5 times to confirm the settings.The LCD will display “03”.
4.
The
Hornby Select Digital Control
unit will now be restored to its factory settings.
The Select is “Factory Set” when manufactured, however some of the basic settings can be altered by the
operator.These settings include the ability to turn On and Off the ability to run an analogue locomotive on the
layout. Other settings can be made to allocate additional controllers (See Walkabout Mode) to the Select
controller.
Control Station - Switching Analogue Mode On/Off:
1.
Press and hold the “STOP”
+
for 1 second. The LCD display will display “C5”
(Command Station).
2.
Press “FUNCTION” to toggle between C5 (Control Station) and HC (Hand Controller) modes. Ensure C5
is shown.
3.
Press “SELECT” to select C5 mode. The LCD will flash twice and display “0”.
4.
Press “FUNCTION” to toggle between 0 (enable) and -0 (disable) to enable/disable analogue locomotive
modes.
5.
Press “SELECT” to confirm your choice.
The RED LED will flash 5 times to confirm the settings.
The LCD will display “03”.
Configuring the Control Unit