Horizont ranger AN50 Скачать руководство пользователя страница 5

ranger AN50 / AN70

8

9

LED

1

OPERATION:

The CONTROL LED 1 lights up green when the device is working trouble-free. If the LED lights red, there is a 

fault. Faults can be caused by:

• 

Rechargeable battery voltage weak, remedy: Recharge the battery

• 

Fence voltage too low: Select MODE NORMAL

• 

ARGUTECTOR value too low, remedy: Free fence from leakage currents (plants, short-circuits, etc.)

• 

In case of interferences in the pulse sequence: Switch off the device for about 30 seconds, contact service 

(see below) if necessary (The device has a pulse interval of approx. 1.5 (normal) or 2 (slow) seconds. The 

device must be repaired immediately if the interval is less than 1 second.)

• 

Activate the display indicators for troubleshooting:

1

The display indicators can be activated with the push-button (1). One of the 6 modes can also be set with the 

push-button (1). The currently set mode is displayed by pressing the button briefly. All modes can then be selec-

ted one by one by continuing to press the button. The mode selected last remains set after exiting the menu. The 

device shows the rechargeable battery, fence voltage and Argutector values again after 5 seconds.

LED

2

The rechargeable battery indicator (LED 2) provides information about the rechargeable battery or battery 

voltage. If the charging voltage of the solar panel/main adapter is greater than the voltage of the rechargeable 

battery/battery, the solar indicator lights steadily in green: The solar panel charges the 12 V rechargeable battery 

but not the 9V battery.

LED

3

Cycle sequence monitoring

The device is fitted with cycle sequence monitoring to prevent inadmissible energy being transferred to the fen-

ce. If the cycle sequence rate falls below 1 second, the device switches off automatically and the LED3 flashes 

up red. Possible causes: Lightning strikes, continuous flashovers on defence, defective device. Isolate the device 

in order to reset the disrupted operation. After switching on again the LED3 must go out, otherwise the device 

must be sent in for repair.

The fence voltage and Argutector indicator shows both values alternately.

The 6 LEDs indicate the fence output voltage in 1.000V steps. The display builds up from the left. For minding 

security at least 3 LEDs (3.000) should light up otherwise the voltage is too low. Possible causes: 

•  With fence:   

 heavy plant growth on the fence, poor insulators, short-circuit on metal posts or fence 

too long

•  Without fence: 

Device is defective, see Service

The 6 LEDs indicate the fence insulation by the Argutector display in 6 stages. The display builds up from the 

right. If all 6 LEDs light up, the fence insulation is good and little energy is required to maintain minding security. 

The less number of LEDs are alight, the poorer the fence insulation due to leakage currents (plant growth, 

branches fallen onto the fence system, short-circuit, poor earthing). Increased energy is required to keep the 

fence secure.  

The following modes can be selected:  

Nor-

mal

1

Normal

Normal pulse sequence (1.5 seconds) The maximum output energy can be achieved. The economy circuit 

regulates automatically. 

SMART

2

SMART 2

Normal pulse sequence (1.5 seconds) Regulation by APN*

3

+

DAY MODE 3

Normal pulse sequence (1.5 seconds) by day, slow pulse sequence (2.0 seconds) at night Regulation by APN*

4

+

NIGHT MODE 4

Slow pulse sequence (2.0 seconds) by day, normal pulse sequence (1.5 seconds) at night Regulation by APN*

5

SLOW MODE 5

 Slow pulse sequence (2.0 seconds) by day and at night Regulation by APN*

6

NIGHT-ONLY MODE 6

No pulse transmission by day, normal pulse sequence (1.5 seconds) at night Regulation by APN*

* APN (Automatic Power Niveau): 

The output energy of the device is set initially to 50% and the actual fence voltage is mea-

sured continuously. If the output voltage is below 5,000 V or drops below this value, the device gradually increases the output 

energy until the output voltage is above 5,000 V or the maximum energy of the device (100%) is reached. In order to ensure the 

minding security with the lowest possible energy requirement, the output power can also be turned down automatically when 

the fence voltage is above the minimum minding voltage of 5,000 V.

This intelligent regulation ensures that the set voltage or minimum minding voltage on the device of 5,000 V is always main-

tained at the same time as optimizing the device‘s energy requirement.

The device is in the „Normal“ mode the first time that it is switched on. If the device is switched off (up to 7 

days) or the rechargeable battery is changed, the device starts back up in the last set mode.  

EARTHING: 

Good earthing of the fence is extremely important for trouble-free operation and optimum performance of the 

device, therefore it should be earthed in a moist and overgrown place if possible. 

Use AN50 = 3 earthing rods (1m long) or AN70 = 5 earthing rods (1m long). If the ground is dry and the fence is 

long, an additional earth conductor with intermediate earths (every 50m) should be laid along the fence.

CHECKING THE EARTHING:

Provoke a short-circuit by driving a metal rod into the ground against the pasture fence wire (not plastic) about 

50 m away from the pasture fence device. The pasture fence device should now only light up maximum 1 LED 

(moist ground) or maximum 2 LEDs (dry ground), otherwise the number and/or length of the earth stakes should 

be increased.

FAULTS:

Disconnect all power sources. Reconnect all power sources after 20 seconds. The device starts up with the last-

used settings after switching „on“. 

  

SERVICE:

 Repair is only to be made by qualified service personnel. 

Only by the manufacturer commanded replacement parts must be used.

SUBJECT TO TECHNICAL ALTERATIONS !

Содержание ranger AN50

Страница 1: ...horizont com ranger AN70 TYPE 10857 ranger AN50 TYPE 10858 ORIGINALBETRIEBSANLEITUNG Elektrozaunger t INSTRUCTION MANUAL Electric Fencer NOTICE D UTILISATION lectrificateur de cl ture INSTRUCCIONES D...

Страница 2: ...gedr ckt halten Nach 1 Sekunde beginnt ein Leuchtdiodentest LED 2 9 von links nach rechts Nach diesem Test erl schen alle LEDs und nach 1 Sekunde h rt man ein gleichm iges Ticken im Rhythmus der Impul...

Страница 3: ...ur Aufrechterhaltung der H tesicherheit wird wenig Energie ben tigt Je geringer die Anzahl der aufleuchtenden LEDs ist desto schlechter ist die Zaunisolation durch Ableitungen Bewuchs Aststurz auf die...

Страница 4: ...r indicator light up If none of the LEDs light up not even the status LED LED1 the 12V rechargeable battery is depleted or the device or the 100 240V mains adapter is defective 12V Fig 3 COMMISSIONING...

Страница 5: ...ht the poorer the fence insulation due to leakage currents plant growth branches fallen onto the fence system short circuit poor earthing Increased energy is required to keep the fence secure The foll...

Страница 6: ...reil envoie des impulsions la cl ture et les affichages LED affichage accu tension de cl ture et Argutector Si aucune des LED ne s allume le statut LED LED1 non plus soit l accu 12V est vide ou bien i...

Страница 7: ...tation chute de branches sur la cl ture court circuit mauvaise mise la terre Une nergie plus est n cessaire pour assurer l efficacit de la cl ture Les modes suivants peuvent tre s lectionn s Nor mal...

Страница 8: ...rgutector brillan Si no se enciende ninguno de los LED s tampoco el LED LED1 de estado o el acumulador de 12Volt est descargado o el dispositivo o la fuente de alimentaci n 100 240Volt tiene un defect...

Страница 9: ...ca da de ramas sobre el vallado cortocircuitos puesta a tierra deficiente Se necesita mayor energ a para mantener la valla con seguridad de cuidado Se pueden seleccionar entre los siguientes modos Nor...

Страница 10: ...ndicadores LED indicador de bateria indica o de tens o na veda o e Argutector acendem Se nenhum dos LED nem o LED1 de estado se acender ou se a bateria de 12V estiverem vazias h um defeito no aparelho...

Страница 11: ...pior o isolamento da veda o por descargas vegeta o queda de ramos sobre a veda o curto circuito m liga o terra necess rio um aumento de energia para manter a condut ncia da corrente na veda o Os segu...

Страница 12: ...iano puliti e che il collegamento ai poli sia corretto Azionare il dispositivo vedi sopra con il tasto a pressione 1 Dopo alcuni secondi viene emesso un ticchettio uniforme ci significa che l apparecc...

Страница 13: ...ne tramite APN 3 DAY MODE 3 Sequenza di impulsi normale 1 5 secondi di giorno sequenza di impulsi lenta 2 0 secondi di notte Regolazi one tramite APN 4 NIGHT MODE 4 Sequenza di impulsi lenta 2 0 secon...

Страница 14: ...ngen LED er lyser heller ikke status LED en LED1 er det genopladelige 12V batteri tomt eller apparatet hhv 100 240V netdelen er defekt 12V Fig 3 IBRUGTAGNING MED GENOPLADELIGT 12V BATTERI EKSTRAUDS TY...

Страница 15: ...nets isolering pga afledninger bevoksning gren faldet ned p hegnet kortslutning d rlig jording Der er brug for mere energi for at garantere en sikker indhegning F lgende modi kan v lges Nor mal 1 Norm...

Страница 16: ...paal worden gemonteerd De aardingsstaaf lange staaf moet op een vochtige plaats zo diep mogelijk in de grond worden geslagen en met een corrosiebestendige draad met aardklem van het apparaat worden v...

Страница 17: ...de drukknop 1 een van de 6 mo dussen instellen Door kort op de knop te drukken wordt de momenteel ingestelde modus weergegeven Door telkens weer op de knop te drukken selecteert u na elkaar de verschi...

Страница 18: ...1m lang plaatsen Bij droge bodem en lang hekwerk moet u een bijkomende aardleiding om de 50 m langs het hekwerk voorzien CONTROLE VAN DE AARDING Op een afstand van ca 50 m van het schrikdraadapparaat...

Страница 19: ...1 Z2 FIG 6 Ersatzteile Spare parts Pi ces d tach es Requesto Pe as Pezzi di ricambio Reservedele Reserve onderdelen 90676U 90150 84701B 84683 84680 607621 89779 ranger AN50 94890 ranger AN70 88148 846...

Страница 20: ...egevens 100 km 3 ranger AN50 ranger AN50 100 km ranger AN70 130 km Fig 8 130 km 3 ranger AN70 CEE max Zaunl nge max fence line length longueur lectrif e longitud m xima del vallado Comprimento m ximo...

Страница 21: ...40...

Отзывы: