3
3-9
3: Adjusting and Checking Procedures
Adjusting and Checking Procedures
3-8
Table Upper Limit Switch S01 Position Adjustment
The table upper limit switch S01 (Fig.1)
detects the upper limit of the feed table.
When the feed table is Up, the sheet loaded
on the feed table is detected by the sheet
upper limit sensor B06 (Fig.2) and the feed
table stops there.
If the sensor B06 malfunctions or the feed
table lifts with an object on it, the upper
guide is raised and the S01 activates to
stop the feed table.
Loosen the fixing screws on table
upper limit switch S01.
Lock the S01 in position that its actua-
tor positions as shown in Fig.3.
Check the followings.
1
Load a couple of sheets on the feed table.
2
Turn ON the power switch.
3
Press the test feed button.
The feed table moves Up.
4
Raise the upper guide manually.
If the table stops and starts lowering, the S01 is
installed correctly.
Fig.1 Table Upper Limit Switch S01
Fig.2 Sheet Upper Limit Sensor B06
Fig.3 S01 Actuator Position
3-8: Table Upper Limit Switch S01 Position Adjustment
Upper Guide
S01
Magnet
S01
Feed Table
B06
Sheet Upper Limit
Sensor
When the actuator
is pushed, there is
still 0.5 mm (0.02")
space.
S01
Nut Plate
Содержание PF-P330
Страница 2: ......
Страница 9: ...1 1 1 1 Mechanism Mechanism 1 Mechanism ...
Страница 21: ...2 2 1 2 Service Mode Service Mode 2 Service Mode ...
Страница 24: ...2 4 2 Service Mode This page is intentionally left blank ...
Страница 36: ...3 12 3 Adjusting and Checking Procedures This page is intentionally left blank ...
Страница 37: ...4 4 1 4 Mechanical Troubleshooting Mechanical Troubleshooting 4 Mechanical Troubleshooting ...
Страница 51: ...5 5 1 5 Folding Quality Troubleshooting Folding Quality Troubleshooting 5 Folding Quality Troubleshooting ...
Страница 58: ...5 8 5 Folding Quality Troubleshooting This page is intentionally left blank ...
Страница 59: ...6 6 1 6 Electrical Circuit Electrical Circuit 6 Electrical Circuit ...
Страница 70: ...6 12 6 Electrical Circuit This page is intentionally left blank ...