P
ART
R
EPLACEMENT
Table of Contents
7.0AT-03
40
Service Manual
Motor Replacement
1. Turn off power to the treadmill and disconnect the power cord.
2. Remove the motor cover as outlined in Section above.
3. Walk the drive belt off the motor pulley.
4. Disconnect the motor cable ground wire from the grounding post.
5. Disconnect the motor cable from the MCB.
6. Remove the 2 screws holding the motor to the frame (Figure A).
Figure A
7. Remove the motor from the treadmill
8. Reverse Steps 1-7 to install a new motor.
NOTE:
Be sure that the motor isolator pad is in place prior to mounting the new motor.