- 7 - 

2)  After turning on power to the Liquid flow meter(LF or XF), input the forced closing 

signal to close the control valve.    (See Instruction Manual for Liquid flow meter.) 

3)  Set the primary pressure (material supply pressure). 

*  The material supply pressure varies depending on the material to be produced and 

product flow rate.    Set the supply pressure, referring to the specification sheet. 

*  Set the pressure for supplying to the tank under pressure in consideration of the 

difference in level between MV and tank, so that the supply pressure to MV is 
identical with the pressure indicated on the individual setting sheet. 

4)  Please control a predetermined carrier gas flow by MFC for carrier gas.   
5)  Supply MV with the liquid material. 

* If the forced closing signal has not been input, the material is supplied at the 

beginning in such a large quantity that all material cannot be vaporized, and the 
material may be left in the liquid state on the secondary side.    Before supplying 
the material, check that the signal has been input. 

*  When the liquid material is introduced, the output signal of the Liqud flow meter (LF 

or XF) temporarily increases.    This is not an error.    The signal will become zero 
when the line to MV is filled with the liquid.  (Check the Liquid flow meter(LF or 
XF) output signal.) 

4.3 Vaporization 

(1)  Feed the necessary carrier gas to the MFC. 
(2)  After the carrier gas flow rate stabilizes, input the setting signal to cancel the forced 

closing signal, and vaporization will be started. 
*  After vaporization is started, check the Liquid flow meter output signal to ensure that 

the flow rate is controlled normally. 

* Immediately after the equipment is started up, gas may be left in the piping, and 

vaporization may be unstable.    Feed the gas into the exhaust line. 

5. Peripheral 

Equipment 

We supply mixing valves and cables designed for this equipment.    The use of these special 
equipments eliminates the necessity of wiring and ensures reliable operations. 

Control unit for Mixing valve   

: PE-D20, etc. 

Cable 

:  SC-ELV (for LF), SC-EDH (for XF) 

 Temperature control unit 

For MV 

  :HC-100VE 

For heating piping  :HC-100VE 

Other various peripheral equipments are available.    See our catalogs. 

Содержание MV-2000

Страница 1: ...Mixing Vaporizer MV 2000 Instruction Manual CODE I031170900...

Страница 2: ...arranties set forth herein shall be extended Any malfunction or damage attributable to improper operation Any malfunction attributable to repair or modification by any person not authorized by HORIBA...

Страница 3: ...to abide by the information in a WARNING may result in serious injury and can be life threatening WARNING CAUTION HOT SURFACE After heating up do not touch the main unit Doing so can burn your hands C...

Страница 4: ...iquid supply line 12 9 2 Clogging by vaporization 13 9 3 Pressure loss of internal nozzles 14 9 4 Valve travel for set temperature 14 9 5 Purging procedures 14 9 6 Temperature control 14 9 7 Setting o...

Страница 5: ...Hz 200 VA Orifice MV 2 4 0 4 mm MV 2 7 0 7 mm MV 2 0 1 0 mm Applicable flow rate 3 MV 2 1 Less than 1 ccm or g min MV 2 2 1 to less than 5 ccm or g min MV 2 3 5 to less than 10 ccm or g min MV 2 4 10...

Страница 6: ...differ in the material of the seat of the flow rate control valve The P PFA type valves are standard because seat leakage owing to particles and product hardly occurs For some materials having high p...

Страница 7: ...3 3 External Dimensions 3 1 without pnuematic valve Unit mm...

Страница 8: ...4 3 2 with pnuematic valve Unit mm...

Страница 9: ...rmine the piping diameter in consideration of piping pressure loss When the liquid material contains particles fit a filter 0 01 m or so in the middle of the line Please select the filter in considera...

Страница 10: ...e CA thermocouples and 200W heaters are used Use temperature regulators and SSRs appropriate to these specifications For MV use temperature regulators having a control period proportional period of 1...

Страница 11: ...ial check that the signal has been input When the liquid material is introduced the output signal of the Liqud flow meter LF or XF temporarily increases This is not an error The signal will become zer...

Страница 12: ...turn off the temperature regulators of MV Disconnect them after the main unit cools off 7 Troubleshooting When any trouble occurs with MV flow control or temperature condition check the following poi...

Страница 13: ...shut off after a temperature fall and a heater power supply when temperature does not rise and you check heater resistance and there is no electrical connection of a heater The heater power supply sh...

Страница 14: ...ing signal to the liquid flow meter LF or XF and check for seat leakage See the remedies stated in the following item Seat leakage The valve cable has not been connected to MV or Liquid flow meter LF...

Страница 15: ...e vaporizer of MV is controlled by the temperature regulator Therefore thermocouple and heater wires are necessary for each regulator Wire the regulator correctly checking the marking on the cables If...

Страница 16: ...ed and turned into air bubbles in the liquid The amount of gas dissolved in the liquid material changes depending on the applied pressure kind of pressure gas kind of liquid material and temperature I...

Страница 17: ...hanges It is necessary to compare the pressure under uniform conditions 2 The valve travel can be monitored by checking the supply voltage to the control valve valve voltage monitor output Since MV is...

Страница 18: ...the piping the material may not be purged completely Therefore for a material having an excessively low vapor pressure it is recommended to provide a branch line for evacuation on the piping for supp...

Страница 19: ...to Item 1 of 9 2 Clogging by vaporization and stop the vaporization before the secondary side is completely blocked If the passage is clogged to stop the flow the values output from the mass flow cont...

Страница 20: ...ll 5 Amp specification of overcurrent protection such as circuit breaker or fuse in the heater power line 1 Temperature regulation in mixing valve MV main unit 2 Temperature regulation in Vaporizer Mi...

Страница 21: ...ate of manufacture as far as the safety and usage precautions for the product are observed Name and amount of toxic hazardous substance or element used in a product Unit name Toxic hazardous substance...

Отзывы: