I
NSTALLATION
8030HEPTA/NCD Network Clock Device - V04.00
21 / 43
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
5.2
Connection LAN Interface ETH0/ETH1
LNK LED (Green)
Description
Off
10 MBit Ethernet detected
On
100 MBit / 1 GBit Ethernet detected
SPD LED (Yellow)
Description
Off
No LAN connection to a network
On
LAN connection available
Flashes
Network activity at ETH0 (transmission
/ reception)
Pin No.
Assignment
1
TX_DA+
2
TX_DA-
3
RX_DB+
4
BI_DC+
5
BI_DC-
6
RX_DB-
7
BI_DD+
8
BI_DD-