13
Check agitator brush roll
When agitator brush roll brushes are
worn, the agitator brush roll should be
replaced.
To check condition of brushes,
turn
cleaner OFF and disconnect from elec-
trical outlet.
Move edge of a card across bot-
tom plate while turning agitator
brush roll. To maintain cleaning effec-
tiveness, replace agitator brush roll if
brushes do not touch card.
40
What to buy
When purchasing a new agitator brush
roll, ask for
HOOVER part no.
48414140
.
How to replace
Turn cleaner ON and rotate mode con-
trol dial to HARD FLOOR. Turn cleaner
OFF and disconnect from electrical out-
let.
Place handle in upright position and
turn cleaner over so bottom side is up.
Remove the five screws as shown
with a Phillips screwdriver. Lift off
bottom plate (A).
41
®
®
(Cont’d)
→
A
B
Agitator brush roll
Pull up on agitator brush roll (C)
to remove from brush roll cavity.
Holding agitator brush roll with
one hand, slide belt (D) off the
agitator brush roll.
43
NOTE:
Hold on to the belt with one
hand. Do not allow the belt to fall back
into the cavity on bottom of cleaner.
42
Hold new agitator brush roll in
one hand; the belt in the other.
Slide the belt onto the agitator brush
roll, positioning the belt in the belt guide
(E) on the agitator brush roll.
44
C
D
E
Содержание U8311