background image

 
 

 

 

 _________________________________________________________________________________________________ 
 

 _____________________________________________________________________________________ 
 
U414_UxA_Bt_e_220802 

 

  

     5/5

                  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Declaration of conformity, Declaration of Incorporation  

 

We,     

  

Höntzsch GmbH & Co. KG 

 

 

 

Gottlieb-Daimler-Str. 37 

 

 

 

D-71334 Waiblingen 

 
 
bearing sole responsibility, hereby declare that the product 
 
 

 

 

flow measuring equipment  

 
 

 

 

UFA-Ex-d measuring tubes FA Di, probes ZS, TS 
UVA-Ex-d measuring tubes VA Di, probes VA40 
UTA-Ex-d measuring tubes TA Di, probes TA10/15 

 
with EC type examination certificate IBExU 06 ATEX 1103 X 
 
referred to by this declaration is in conformity with the following standards or normative documents: 

Provisions of the Directive 
 

Reference no. and date of issue 
 

2014/34/EU: Equipment and Protective Systems in 
Potentially Explosive Atmospheres 
 

EN 60079-0: 2018 
EN 60079-1: 2014 
EN 60079-7: 2015 
EN 60079-11: 2012 
EN 60079-26: 2015 

  

 

EN 60079-31: 2014 
 

2014/30/EU: Electromagnetic Compatibility 
 

EN 61000-6-4: 2007 + A1: 2011 
EN 61000-6-2: 2006 + Corrigendum 1: 2011 
 

2014/68/EU: Pressure Equipment Directive 
 

 
 
 

 

One or more of these standards referred to in the EC type examination certificate have been replaced by 
new versions. We declare that we are also in agreement with these new versions. 
 

 

 

 

 

 

 

 

 

 

 

Waiblingen, 02.08.2022 

 

 

        Jürgen Lempp / Managing Director  

 

 

 
 
 
 
 
 
 
 

Subject to alteration 

 

Höntzsch GmbH & Co. KG 
Gottlieb-Daimler-Straße 37 
D-71334 Waiblingen  
Telefon 

+49 7151 / 17 16-0 

E-Mail 

[email protected] 

Internet  www.hoentzsch.com

 

Содержание UFA-Ex-d FA Di

Страница 1: ... the corresponding technical documents is not exceeded With the TT version the terminal clamps must not be used at temperatures below 20 C The temperature of the medium in category 1 2G areas must not exceed 60 C under atmospheric pres sure For UFA and UVA the maximum admissible temperature of the medium in category 2G areas corre sponds to the temperature class For UTA the maximum admissible temp...

Страница 2: ...d both inside and outside the explosive atmospheres when installing Titanium sensors UFA only have approval for applications in zone 1 category 2G areas unless fitted with additional preventive measures e g safety mesh 2 Technical Data EC type examination certificate IBExU 06 ATEX 1103 X UFA and UVA Marking Explosion protection Ex ia db eb ia IIC T6 Ga Gb Marking Explosion protection Ex ia tb IIIC...

Страница 3: ...s designed for cross sections of 4 6 mm Use a cable lug The torque for fixture to the earth terminal must amount to 2 3 Nm Cables are connected to the protection type e terminal blocks in the terminal compartment via two protec tion type e cable glands Condition as supplied to customer one e cable gland and one e screw plug Cable glands M20 thread are used for cables with an exterior diameter of 5...

Страница 4: ..._______________________________________________________________ 4 5 U414_UxA_Bt_e_220802 Analog output connection Power supply connection Electrical Connections Shielding terminals inside the Ex d housing terminal compartment Protective ground terminal on the outside of the housing Equipotential bonding 24 V DC 20 27 V DC ...

Страница 5: ...conformity with the following standards or normative documents Provisions of the Directive Reference no and date of issue 2014 34 EU Equipment and Protective Systems in Potentially Explosive Atmospheres EN 60079 0 2018 EN 60079 1 2014 EN 60079 7 2015 EN 60079 11 2012 EN 60079 26 2015 EN 60079 31 2014 2014 30 EU Electromagnetic Compatibility EN 61000 6 4 2007 A1 2011 EN 61000 6 2 2006 Corrigendum 1...

Отзывы: