Analog outputs (2 x)
: 0 ... 10 V with internal resistance of 1000 Ohm; measured, initial and
final values adjustable as appropriate
Analog input 4-20 mA
: for connection of sensor in 2-wire system with
12 V;
allocation of unit, initial value and final value adjustable
Analog input 0-10 V
: for connection of sensors with voltage output; input resistance 5 MOhm;
12 V power supply for sensors, max. 100 mA; allocation of unit, initial
value and final value adjustable
3.4
Measurement uncertainty
Input FA
: +/- 1 Hz
Input VA
: +/- 1 Hz
Input TA
: +/- 1 (0.7 % of measured value + 0.02 % FS)
Temperature display
: +/- 1 Kelvin
Analog input 0-10 V
: +/- 1 (0.3 % of measured value + 0.02 % FS)
Analog input 4-20 mA
: +/- 1 (0.3 % of measured value + 0.02 % FS)
Input Pt100
: +/- 0.2 Kelvin
Analog output 1+2, 0-10 V
: +/- 1 (0.2 % of measured value + 0.02 % FS)
All values apply for a set damping rate of 30 seconds during measurement. In addition, the measurement
uncertainty of the utilised sensors must be taken into consideration.
4
Initial Operation / Startup
For installation and operation of the system, especially in category 3G, the national regulations
currently in force, the recognised standards of good practice and these Operating Instructions
apply.
4.1
Connector sockets
5-pin connector socket:
for thermal sensors TA10 and TADi measuring tubes
8-pin connector socket:
for vane wheel sensors FA, FAR, FT and FADi measuring tubes
for vortex sensors VA, VAT and VADi measuring tubes
for temperature sensors Pt100