DEVICE DESCRIPTION
8
VERSAFLOW VORTEX 200
www.honeywellprocess.com
34-VF-25-137 iss.1 GLO July 2019 US
2.5 Types of protection
Electronics compartment
Ex db (Gb) or Ex tb (Db)
Ex db (Gb) or Ex tb (Db)
Ex db (Gb) or Ex tb (Db)
Ex db (Gb) or Ex tb (Db)
Terminal compartment
either Ex db or Ex eb (Gb) or Ex tb (Db)
either Ex db or Ex eb (Gb) or Ex tb (Db)
either Ex db or Ex eb (Gb) or Ex tb (Db)
either Ex db or Ex eb (Gb) or Ex tb (Db)
Flow sensor
Ex ia (Gb or Db)
Ex ia (Gb or Db)
Ex ia (Gb or Db)
Ex ia (Gb or Db)
Table 2-1: Used types of protection
ATEX
II 2 G
II 2 G
II 2 G
II 2 G
Ex db ia IIC T6...T2 Gb
Ex db ia IIC T6...T2 Gb
Ex db ia IIC T6...T2 Gb
Ex db ia IIC T6...T2 Gb
or
Ex db eb ia IIC T6...T2 Gb
Ex db eb ia IIC T6...T2 Gb
Ex db eb ia IIC T6...T2 Gb
Ex db eb ia IIC T6...T2 Gb
IECEx
Ex db ia IIC T6...T2 Gb
Ex db ia IIC T6...T2 Gb
Ex db ia IIC T6...T2 Gb
Ex db ia IIC T6...T2 Gb
or
Ex db eb ia IIC T6...T2 Gb
Ex db eb ia IIC T6...T2 Gb
Ex db eb ia IIC T6...T2 Gb
Ex db eb ia IIC T6...T2 Gb
Table 2-2: Marking for the flameproof version of compact versions
ATEX
II 2 G
II 2 G
II 2 G
II 2 G
Ex db [ia] IIC T6 Gb
Ex db [ia] IIC T6 Gb
Ex db [ia] IIC T6 Gb
Ex db [ia] IIC T6 Gb (signal converter)
or
Ex db eb [ia] IIC T6 Gb
Ex db eb [ia] IIC T6 Gb
Ex db eb [ia] IIC T6 Gb
Ex db eb [ia] IIC T6 Gb
II 2 G
II 2 G
II 2 G
II 2 G
Ex ia IIC T6...T2 Gb
Ex ia IIC T6...T2 Gb
Ex ia IIC T6...T2 Gb
Ex ia IIC T6...T2 Gb (flow sensor)
IECEx
Ex db [ia] IIC T6 Gb
Ex db [ia] IIC T6 Gb
Ex db [ia] IIC T6 Gb
Ex db [ia] IIC T6 Gb (signal converter)
or
Ex db eb [ia] IIC T6 Gb
Ex db eb [ia] IIC T6 Gb
Ex db eb [ia] IIC T6 Gb
Ex db eb [ia] IIC T6 Gb
Ex ia IIC T6...T2 Gb
Ex ia IIC T6...T2 Gb
Ex ia IIC T6...T2 Gb
Ex ia IIC T6...T2 Gb (flow sensor)
Table 2-3: Marking for the flameproof version of remote versions
ATEX
II 2 D
II 2 D
II 2 D
II 2 D
Ex tb ia IIIC T70
Ex tb ia IIIC T70
Ex tb ia IIIC T70
Ex tb ia IIIC T70
°
C...T240
C...T240
C...T240
C...T240
°
C Db
C Db
C Db
C Db
IECEx
Ex tb ia IIIC T70
Ex tb ia IIIC T70
Ex tb ia IIIC T70
Ex tb ia IIIC T70
°
C...T240
C...T240
C...T240
C...T240
°
C Db
C Db
C Db
C Db
Table 2-4: Marking for the dustproof version of compact versions
ATEX
II 2 D
II 2 D
II 2 D
II 2 D
Ex tb [ia] IIIC T70
Ex tb [ia] IIIC T70
Ex tb [ia] IIIC T70
Ex tb [ia] IIIC T70
°
C Db
C Db
C Db
C Db (signal converter)
II 2 D
II 2 D
II 2 D
II 2 D
Ex ia IIIC T70
Ex ia IIIC T70
Ex ia IIIC T70
Ex ia IIIC T70
°
C...T240
C...T240
C...T240
C...T240
°
C Db
C Db
C Db
C Db (flow sensor)
IECEx
Ex tb [ia] IIIC T70
Ex tb [ia] IIIC T70
Ex tb [ia] IIIC T70
Ex tb [ia] IIIC T70
°
C Db
C Db
C Db
C Db (signal converter)
Ex ia IIIC T70
Ex ia IIIC T70
Ex ia IIIC T70
Ex ia IIIC T70
°
C...T240
C...T240
C...T240
C...T240
°
C Db
C Db
C Db
C Db (flow sensor)
Table 2-5: Marking for the dustproof version of remote versions