TROUBLESHOOTING

WARNING

Electrical Shock Hazard.

Can cause serious injury or death.

Use extreme caution while troubleshooting; line 
voltage is present.

IMPORTANT

Do not replace the valve until all other sources of 
trouble are eliminated.

Troubleshooting Procedure

If the valve does not open when the thermostat or controller 
calls for heat:

1.

Check for line voltage at the valve leadwires or terminal 
block.

2.

If there is no voltage at the valve leadwires or terminal 
block, make sure:
a. line voltage power is connected to the master 

switch;

b. master switch is closed and overload protection 

(circuit breaker, fuse or similar device) has not 
opened the power line.

3.

If there is still no voltage at the valve leadwires or 
terminal block, make sure all appropriate contacts in the 
thermostat or controller, limits and flame safeguard 
controls are closed. If one or more are open, determine 
the cause(s); correct the trouble, and proceed.

4.

If there is proper voltage at the valve but the valve still 
does not open, check for normal gas pressure.

5.

If the valve still does not open, replace the valve.

If the valve does not close when one or more of the 
appropriate contacts in the thermostat, controller, limits or 
flame safeguard control is open:

1.

Make sure the valve is wired in the correct circuit.

2.

Open the master switch to remove power from the 
valve.

3.

If the valve closes now, check the wiring for the valve 
and correct the wiring as necessary.

4.

Check for a short in the electrical circuit and repair it as 
necessary.

SERVICE INFORMATION

WARNING

Explosion Hazard and Electrical Shock Hazard.

Can cause explosion, serious injury or death.

Turn off gas supply and disconnect all electrical power 
to the valve before servicing.

IMPORTANT

Only trained, experienced flame safeguard control 
technicians should attempt to service or repair flame 
safeguard controls and burner assemblies.

Scheduled Inspection and Maintenance

Set up and follow a schedule for periodic inspection and 
maintenance, including the burner, all other controls and the 
valve(s). It is recommended that the valve leak test in the 
Checkout section be included in this schedule. Refer to the 
instructions for the primary safety control(s) for more 
inspection and maintenance information.

Содержание V4297A Series

Страница 1: ...alve body small applicable to five pipe sizes 3 4 in 19 mm 1 in 25 mm 1 1 4 in 32 mm 1 1 2 in 38 mm and 2 in 51 mm pipes Two valves with different capacities V4297A1005 1 in 25 mm internal opening small capacity V4297A1013 2 in 51 mm internal opening high capacity Two 1 4 in NPT upstream and one 1 4 in NPT downstream pressure taps and plugs Accepts C6097 Pressure Switch mounted directly to flange ...

Страница 2: ...s listed Also this product is tested and calibrated under closely controlled conditions and some minor differences in performance can be expected if those conditions are changed Models V4297A1005 small body 1 in 25 mm internal opening small capacity V4297A1013 small body 2 in 51 mm internal opening high capacity Types of Gas Natural manufactured mixed or LP only Gas Train Pipe Size 3 4 in 19 mm 1 ...

Страница 3: ...00 100 1 000 10 000 30 000 10 1 0 1 PRESSURE DROP IN WC FLOW CAPACITY cfh M16534 Propane sp gr 1 53 Natural Gas sp gr 0 64 LEGEND 100 100 1 000 10 000 30 000 10 1 0 1 PRESSURE DROP IN WC FLOW CAPACITY cfh M16535 Propane sp gr 1 53 Natural Gas sp gr 0 64 LEGEND 100 100 1 000 10 000 30 000 10 1 0 1 PRESSURE DROP IN WC FLOW CAPACITY cfh M16536 Propane sp gr 1 53 Natural Gas sp gr 0 64 LEGEND 100 100 ...

Страница 4: ...al connections Current Draw V4297A1005 small capacity 120V 0 2A V4297A1013 high capacity 120V 0 5A Valve Opening Time 1 sec Valve Closing Time 1 sec Dimensions See Fig 10 and 11 Weight V4297A1005 8 lb 3 6 kg V4297A1013 14 lb 6 3 kg Replacement Parts BBA51315 Coil for V4297A1005 BBA51318 Coil for V4297A1013 Accessories Pipe Adapters 32000109 001 3 4 in NPT 32000109 002 1 in NPT 32000109 003 1 1 4 i...

Страница 5: ...esign Certified Factory Mutual FM Approved KTCPI001 Visual Position Indicator required if used with pipe size larger than 3 4 in NOTE NOTE Some application codes such as NFPA require visual indication of the valve position as provided by the KTCPI001 Visual Position Indicator 2 51 5 127 5 1 2 140 5 5 8 143 2 1 2 64 1 1 2 38 2 51 2 3 4 70 1 2 13 5 3 4 147 5 5 8 143 9 229 M16541 TOP VIEW 2 51 5 127 ...

Страница 6: ...uctions on mounting a V4297A in a Honeywell Integrated Valve Train System Refer to the installation instructions packed with the Honeywell KTCPI001 Visual Position Indicator for mounting instructions of the indicator WIRING 1 Make sure all wiring agrees with all applicable local codes ordinances and regulations An opening is provided to accommodate rigid conduit or armored cable for line voltage o...

Страница 7: ...gas cock A 7 Run the V4297A Valve to is open position through the safety system then immediately de energize the system to close the V4297A Valve 8 Immerse a 1 4 in 6 mm tube vertically 1 2 in 13 mm into a jar of water 9 Slowly open the manual test petcock F 10 When the rate of bubbles coming through the water stabilizes count the number of bubbles appearing during a ten second period Each bubble ...

Страница 8: ... terminal block make sure all appropriate contacts in the thermostat or controller limits and flame safeguard controls are closed If one or more are open determine the cause s correct the trouble and proceed 4 If there is proper voltage at the valve but the valve still does not open check for normal gas pressure 5 If the valve still does not open replace the valve If the valve does not close when ...

Отзывы: