26
69-2028—01
Outdoor Temperature Low Limit Setting
The Outdoor Low Limit setting is used to activate an
alert when the displayed outdoor temperature on the
thermostat is lower than the value you set. The
setting range is -40° F (-40° C) to 105° F (40° C) in 1°
increments. The factory default setting is 40° F (4° C).
When a thermostat displays a temperature lower than
your low limit setting and your dial-out alert is active,
the TAM dials out.
NOTE: In order for this feature to be enabled, an
optional outdoor temperature sensor must be
installed.
CAUTION
Property Loss Hazard.
Do not assume your designate received
and acted on the active alert.
Prepare to act promptly; time may be critical.
CAUTION
Property Loss Hazard.
Do not rely only on the Telephone Access
Module to identify potential problems in
your home (like detecting low outdoor
temperatures that can freeze water pipes).
Have someone periodically check your home
while you are away.
If your outdoor low limit setting is set to the factory
setting, you hear “
The low limit setting is 40°F (4°C)
.”
If your outdoor low limit setting is correct, and the
value you want, press the * key to return to the Main
menu.
CHANGING THE OUTDOOR TEMPERATURE LOW LIMIT
SETTING
1.
You hear “
To change the outdoor low limit set-
ting, press 3
.”
2.
Press 3.
• You hear “
Enter the low limit setting followed
by the # key
.”
3.
Enter a Low Limit Setting from -40° F (-40° C) to
105° F (40° C) in 1° increments and press the #
key.
• You hear “
Your low limit setting is (your low
limit setting)
.”
4.
If this is the low limit setting you want pro-
grammed, press the * key to return to the Main
menu.
If the outdoor low limit setting is not entered correctly,
you hear “
Invalid setting
.” Follow the instructions
above to enter a new outdoor low limit.