Fig. 1. Internal view of T810D with adjustable heat 

anticipator.

Wiring and Mounting

All wiring must comply with local codes and ordinances.

For 750mV installations, use Table 1 to determine the 
maximum wiring run length.

1.

In replacement applications, inspect the old wires 
for frayed or cracked insulation. Replace any wires 
in poor condition. In new installations, run two 
wires to the chosen location.

2.

Grasp the thermostat cover at the sides with one 
hand. Pull outward on the left edge of the cover 
until it snaps free of the thermostat base. Remove 
and discard the shipping tab that protects the 
switch contacts during shipping.

3.

Connect the thermostat wires to the appropriate 
terminals on the back of the thermostat. See Fig. 2 
and 3 for typical hookup diagrams. Push any 
excess wire back through the hole and plug any 
opening to prevent drafts that could affect thermo-
stat performance.

4.

Adjust the heat anticipator (T810D models only) to 
match the current draw of the primary control in the 
system. See Heat Anticipator Setting (T810D) sec-
tion.

5.

Fasten the thermostat to the wall or outlet box with 
screws through the mounting holes at each side of 
the device. See Fig. 1. Level the thermostat for 
best appearance.

6.

Replace the thermostat cover.

Fig. 2. T810D in typical gas heating system.

Fig. 3. Typical hookup for TS810B in millivolt system.

Fig. 4. Internal schematic for all standard and 

positive Off heating models.

Table 1. Maximum Wiring Length.

Wire

Size

Maximum Length 

2-Wire Cable

Maximum 

Combined Length 

2-Single Wires

(ft)

(m)

(ft)

(m)

No. 18

30

9.0

60

19.0

No. 16

50

15.0

100

30.0

No. 14

80

24.5

160

49.0

MOUNTING HOLES (THERMOSTAT 
TO WALL OR OUTLET BOX)

MOUNTING HOLES (THERMOSTAT 
TO WALL OR OUTLET BOX)

TEMPERATURE
SETTING LEVER

MOUNTING CLIPS  
(2) (FOR COVER)

SNAP SWITCH
CONTACTS

ADJUSTABLE HEAT
ANTICIPATOR SCALE

MOUNTING POSTS (4)
(FOR COVER) 

ADJUSTABLE HEAT ANTICIPATOR
INDICATOR LEVER

BIMETAL ELEMENT BEHIND 
HEAT ANTICIPATOR SCALE

M11700

.3

.6

.8

.4

.1

TH

L1

(HOT)

L2

1

TH

TR

TR

1

POWER SUPPLY.  PROVIDE DISCONNECT MEANS AND 
OVERLOAD PROTECTION AS REQUIRED.

M3607

LIMIT

FAN

T810

GAS VALVE

COMBINATION FAN 
AND LIMIT CONTROL

FAN
MOTOR

TRANSFORMER

1

1 TS810B IS MOUNTED VERTICALLY.

M11701

TS810B THERMOSTAT

TH1

TH2

PP

PP

LIMIT

CONTROL

PILOT CONTROL
(IF USED)

MILLIVOLT
GENERATOR

1

1 MANUAL OFF SWITCH (TEMPERATURE SETPOINT LEVER).

PROVIDES COMPLETE CONTROL CIRCUIT SHUTOFF.  DOES
NOT REPLACE POWER SUPPLY DISCONNECT SWITCH.

M3642

TEMPERATURE 
FALL

TEMPERATURE 
FALL

STANDARD HEATING MODEL

POSITIVE OFF HEATING MODEL

Содержание T810D

Страница 1: ...ad these instructions carefully Failure to follow them could damage the product or cause a hazard ous condition 2 Check the ratings given in the Instructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After installation is complete check out product operation as provided in these instructions CAUTION E...

Страница 2: ...mounting holes at each side of the device See Fig 1 Level the thermostat for best appearance 6 Replace the thermostat cover Fig 2 T810D in typical gas heating system Fig 3 Typical hookup for TS810B in millivolt system Fig 4 Internal schematic for all standard and positive Off heating models Table 1 Maximum Wiring Length Wire Size Maximum Length 2 Wire Cable Maximum Combined Length 2 Single Wires f...

Страница 3: ...to a low setting so the contacts are broken In cold weather it may be necessary to hold the switch so the controls remain open Allow the system to operate through the ammeter for one minute Adjust the anticipator to match the meter reading NOTE For best performance the heat anticipator can require further adjustment To lengthen burner on time move the indicator in the direction of the longer arrow...

Страница 4: ...l com yourhome T810D TS810B HEATING THERMOSTATS Automation and Control Solutions Honeywell International Inc Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 ...

Страница 5: ...entes instructions Le fait de ne pas les suivre risque d endommager le produit ou pourrait constituer un danger 2 Vérifier les caractéristiques nominales indiquées dans les instructions et sur le produit et s assurer que l appareil convient à l application prévue 3 L installateur doit être un technicien d expérience ayant reçu une formation pertinente 4 Une fois l installation terminée vérifier le...

Страница 6: ...au le thermostat à des fins esthétiques 6 Remettre le couvercle sur le thermostat Fig 2 Le T810D dans un système type de chauffage au gaz Fig 3 Raccordement type du TS810B dans un système à tension millivolt Fig 4 Schéma interne pour tous les modèles pour chauffage standard et à coupure à OFF Tableau 1 Longuer maximale des fils Calibre de fils Longueur maximum Câble bifilaire Longueur combinee max...

Страница 7: ...pérature suffisamment basse pour couper les contacts Par temps froid il faut parfois tenir les contacts pour que les commandes restent ouvertes Faire fonctionner le système en laissant l ampèremètre branché pendant une minute Régler l anticipateur pour qu il indique la même grandeur que celle de l ampèremètre REMARQUE Pour un meilleur rendement il est parfois nécessaire d effectuer d autres réglag...

Страница 8: ...rhome THERMOSTATS DE CHAUFFAGE T810D ET TS810B Solutions de régulation et d automatisation Honeywell International Inc Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 ...

Отзывы: