58
www.honeywell.com/sensing
EX Series
Standard
Explosion
Proof
Switches
The EX Series features the smallest UL listed housings available for use in
hazardous locations. Flame paths within the housing cool exploding gases
below the kindling temperature before they reach the explosive gases
surrounding the housing.
Options available include single or double conduit connection.
These switches are not sealed against liquids and should not be used where
there will be liquid splash. If a weather sealed explosion proof switch is
required please select from the CX or LSX/BX series.
Sealing:
NEMA 1, 7 (Class I, Division I, Groups C, D)
9, (Class II, Division I, Groups E, F, G)
Operating temperature:
Standard
-40 °C to 71 °C (-40 °F to 160 °F)
High
100 hr @ 400 °F
Approvals:
UL, CSA
Conduit:
½ in - 14NPT
Contacts:
Silver
Electrical ratings:
A
UL/CSA Rating:
15 A, 125, 250 or 480 Vac;
1
/
8
Hp, 125 Vac; ¼ Hp, 250 Vac;
½ A, 125 Vdc; ¼ A, 250 Vdc.
B
UL/CSA Rating:
20 A, 125, 250 or 480 Vac;
10 A, 125 Vac “L”;
1 Hp, 125 Vac; 2 Hp, 250 Vac;
½ A, 125 Vdc; ¼ A, 250 Vdc.
C
UL/CSA Rating:
10 A, 125 or 250 Vac;
0.3 A, 125 Vdc; 0.15 A, 250 Vdc
.
D
UL/CSA Rating:
10 A, 125, 250 or 480 Vac;
½ A, 125 Vdc; ¼ A, 250 Vdc.
E
UL Rating:
1 A, 125 Vac.
Switching options:
SPDT
DPDT
Single Pole, Double Throw
Double Pole, Double Throw
Snap action contacts (1NC/1NO)
Snap action contacts (2NC/2NO)
Side rotary actuated switches
OPTIONS
No lever
Note: Levers are ordered separately (see pages 69-71
for details)
Operating force max. (OF):
Electrical rating A
0,22 N m (31.25 in oz)
Electrical rating B
3,34 N to 8,90 N (0.75 lb to 2.0 lb)
Pretravel max. (PT):
5,56 mm (0.219 in) 8°
Overtravel max. (OT):
Electrical rating A
90°
Electrical rating B
25°
Differential travel max. (DT):
Electrical rating A
0,18 mm (0.007 in) 0.25°
Electrical rating B
0,3 mm (0.012 in) 4°
ACTUATION
CONTACT
ELECTRICAL RATING
REFERENCE
CW
SPDT
A
EX-AR20
CCW
SPDT
A
EX-AR230
CW
SPDT
B
EXA-AR20
Actuators
EXPLOSION PROOF SWITCHES
Содержание Switches and Sensors
Страница 6: ...4 www honeywell com sensing Blank page ...
Страница 28: ...26 www honeywell com sensing COMPACT LIMIT SWITCHES Blank page ...
Страница 47: ...45 www honeywell com sensing HEAVY DUTY LIMIT SWITCHES Operating temperatures Environmental seal performance ...
Страница 56: ...54 www honeywell com sensing Blank page ...
Страница 70: ...68 www honeywell com sensing Blank page ...
Страница 94: ...92 www honeywell com sensing Blank page ...
Страница 118: ...116 www honeywell com sensing LINEAR AND ROTARY POSITION Blank page ...