![Honeywell Switches and Sensors Скачать руководство пользователя страница 142](http://html.mh-extra.com/html/honeywell/switches-and-sensors/switches-and-sensors_brochure_153758142.webp)
140
www.honeywell.com/sensing
PRESSURE SENSORS
TLD Series
OPTIONS
Flow-through/Output Signal 4 mA to 20 mA
MEASUREMENT TYPE
PRESSURE RANGE
CONNECTIONS
REFERENCE
Compound
-14.7 psig to 100 psig
1/4 in. OD 0.035 in. wall, 1/4 in long tube stub
TLDF4CVT4V100CP
Compound
-14.7 psig to 100 psig
1/4 in. female face seal, swivel
TLDF4CVVFV100CP
Compound
-14.7 psig to 100 psig
1/4 in. female face seal, swivel
TLDF4BSVFV100CP
Flow-through/Output Signal 0 Vdc to 5.0 Vdc
MEASUREMENT TYPE
PRESSURE RANGE
CONNECTIONS
REFERENCE
Compound
-14.7 psig to 100 psig
1/4 in. OD 0.035 in. wall, 1/4 in long tube stub
TLDF5CVT4V100CP
Single Port/Output Signal 4 mA to 20 mA
MEASUREMENT TYPE
PRESSURE RANGE
REFERENCE
Compound
-14.7 psig to 100 psig
1/4 in. female face seal, swivel
TLDS4BNVFV100CP
Flow-through display orientation and transducer location
z
s
72,4
2.85
38,1
1.50
35,9
1.42
26,1
1.03
CABLE
2 COND
1,8 m (6 ft)
38,1
1.50
82,5
3.25
z
s
38,1
1.50
38,1
1.50
z
s
38,1
1.50
38,1
1.50
72,4
2.85
38,1
1.50
CABLE
2 COND
1,8 m (6 ft)
z
s
38,1
1.50
82,5
3.25
26,1
1.03
35,9
1.42
77,0
3.03
42,7
1.68
CABLE
2 COND
1,8 m (6 ft)
BF - Transducer at bottom, front display orientation
BS - Transducer at bottom, side display orientation
CV - Transducer at center back,
vertical display orientation
CH - Transducer at center back,
horizontal display orientation
With space at a premium in semiconductor gas distribution systems, the Series TLD pressure transducer with local
display offers an integrated solution that reduces the overall height of the transducer/display assembly to as little as 3.5
in [88,9 mm]. To accomplish this, the transducer’s signal amplifier is mounted within the display, with the added benefit
of zero and span adjustments conveniently located on the LED display face.
Supply voltage:
12.0 Vdc to 30.0 Vdc
Signal conditioning:
Amplified compensated
Operating temperature range:
-40 °C to 85 °C (-40 °F to 185 °F)
Compensated temperature range:
0 °C to 70 °C (32 °F to 158 °F)
Termination type:
1,83 m (6 ft) 2-conductor cable
Содержание Switches and Sensors
Страница 6: ...4 www honeywell com sensing Blank page ...
Страница 28: ...26 www honeywell com sensing COMPACT LIMIT SWITCHES Blank page ...
Страница 47: ...45 www honeywell com sensing HEAVY DUTY LIMIT SWITCHES Operating temperatures Environmental seal performance ...
Страница 56: ...54 www honeywell com sensing Blank page ...
Страница 70: ...68 www honeywell com sensing Blank page ...
Страница 94: ...92 www honeywell com sensing Blank page ...
Страница 118: ...116 www honeywell com sensing LINEAR AND ROTARY POSITION Blank page ...