101
www.honeywell.com/sensing
LINEAR AND ROTARY POSITION
AQLT/AQMLT Series
Shaftless, waterproof linear position
transducer
The AQLT and AQMLT are shaftless waterproof linear potentiometers designed
to operate in wet/washdown and in-tank environments.
The AQ series features an external actuator magnetically coupled to a position
feedback element. The magnetic actuator replaces the shaft, found in
traditional linear transducers, and eliminates the need for additional stroke
length mounting space.
Precious metal dual wipers, MystR
®
proprietary conductive plastic, and
anodized aluminum housings provide long life and reliable operation in
numerous applications.
Operating temperature:
-40 °C to 80 °C (-40 °F to 176 °F)
Supply voltage (max.):
30 Vdc
Linearity:
± 1.0 %
Starting force (max.):
AQMT 56,7 g (2.0 oz)
AQMLT 28,35 g (1.0 oz)
Sealing:
IP68
Termination:
Cable
AQLT Series
Housing length:
= Electrical 54,87 mm (2.16 in)
Mechanical travel:
= Electrical travel + 2,54 mm (0.1 in)
BLACK
CABLE END
RED
BROWN
ELECTRICAL TRAVEL
PLUS 2.16" (54,86)
0.76
(19,30)
0.20
(5,08)
Ø 0.50
(12,7)
3 WIRE JACKETED CABLE (9/64 Ø)
#28 AWG CONDUCTOR
10 FEET LONG
COLOR CODED PER SCHEMATIC
AREA AVAILABLE FOR CLAMPING
WITHOUT RESTRICTING ELECTRICAL TRAVEL
Ø 0.516
(13,11)
Ø 0.156
(3,96)
Ø 0.813
(20,65)
BOLT CIRCLE
#4-40 UNC THD
6 PLACES
Dimensions in inches (mm)
Ø 1.25
(31,75)
0.024 (0,61)
OFF CENTER
0.25
(6,35)
0.50
(12,70)
1.125 ±0.010
(28,575 ±0,25)
120˚
120˚
1.00 ±0.010
(25,4 ±0,25)
ELECTRICAL TRAVEL
TOTAL RESISTANCE
REFERENCE
(MM (IN))
(OHM)
152,4 (6.0)
6000
AQLT06N06KFC
304,8 (12.0)
12000
AQLT12N12KFC
457,2 (18.0)
18000
AQLT18N18KFC
609,6 (24.0)
24000
AQLT24N24KFC
762,0 (30.0)
30000
AQLT30N30KFC
965,2 (38.0)
38000
AQLT38N38KFC
AQMLT Series
Housing length:
= Electrical 38,1 mm (1.5 in)
Mechanical travel:
= Electrical travel + 2,54 mm (0.1 in)
AREA AVAILABLE FOR CLAMPING
WITHOUT RESTRICTING ELECTRICAL OR
MECHANICAL TRAVEL
Dimensions are in inches (mm)
0.52
(13,2)
0.20
(5,1)
Ø 0.375
(9,5)
ELECTRICAL TRAVEL PLUS 1.5 (38,1) MAX
3 WIRE JACKETED CABLE, Ø 0.14 (3,57)
#28 AWG CONDUCTOR
10 FEET LONG (3,05 M)
COLOR CODED PER SCHEMATIC
Cable End
Black
Red
Wiper
Brown
Schematic
Ø 1.125
(28,58)
Ø 0.388
(9,78)
Ø 0.156
(3,96)
120˚
120˚
Ø 0.690
(17,53)
BOLT CIRCLE
0.125
(3,18)
0.024
(0,60)
OFF CENTER
#4-40 UNC THD
4 PLACES
0.500
(12,70)
1.000
(25,40)
0.250
(6,35)
ELECTRICAL TRAVEL
TOTAL RESISTANCE
REFERENCE
(MM (IN))
(OHM)
12,7 (0.5)
750
AQMLTR5N00750FC
25,4 (1.0)
1500
AQMLT01N01500FC
76,2 (3.0)
3000
AQMLT03N04500FC
152,4 (6.0)
9000
AQMLT06N09000FC
228,6 (9.0)
13500
AQMLT09N13500FC
304,8 (12.0)
18000
AQMLT12N18000FC
Содержание Switches and Sensors
Страница 6: ...4 www honeywell com sensing Blank page ...
Страница 28: ...26 www honeywell com sensing COMPACT LIMIT SWITCHES Blank page ...
Страница 47: ...45 www honeywell com sensing HEAVY DUTY LIMIT SWITCHES Operating temperatures Environmental seal performance ...
Страница 56: ...54 www honeywell com sensing Blank page ...
Страница 70: ...68 www honeywell com sensing Blank page ...
Страница 94: ...92 www honeywell com sensing Blank page ...
Страница 118: ...116 www honeywell com sensing LINEAR AND ROTARY POSITION Blank page ...