44
www.honeywell.com/sensing
HEAVY DUTY LIMIT SWITCHES
HDLS Series
Heavy Duty Limit
Switches
The HDLS Series Heavy Duty Limit Switches offer a wide choice of mounting and actuator options.
Housed in a rugged, die-cast zinc body which is epoxy coated for protection, they are perfectly suited to
special applications in harsh duty environments where conventional limit switches may not be used.
Versatile and full featured, they are designed for long life.
Listings referenced in this section are mainly standard. Low temperature and fluorocarbon (FC, high
temperature) construction is available in all forms of HDLS limit switches. For temperature ranges see
table opposite. Also available are factory sealed, pre-wired switches.
Low temperature switches
have fluorosilicone diaphragm, shaft seals and external boot seal (where
applicable) plus a low temperature lubricant. If prewired with cable, temperature limits are -10 °C (14 °F)
flex and -30 °C (22 °F) no flex.
To order a low temperature version insert the additional letters
Y
and
B
as in the following example:
LSA1A - standard side rotary plug-in switch
LS
Y
A
B
1A - low temperature version.
Completely fluorocarbon (FC) sealed, high temperature, chemical resistance switches
have a full FC
body gasket covering the switch cavity. Rotary types have an extra FC seal on the operating shaft, while
plunger versions have FC boot seals. They are for use in applications where the environment includes
fire-resistant synthetic fluids. The additional FC seals also promote longer operating life for rotary
actuacted HDLS switches in applications where the temperatures are normally -12 °C to 121 °C (10 °F to
250 °F). If prewired with cable, temperature limits are 105 °C (221 °F) dry and 60 °C (140 °F) wet.
To order a fluorocarbon (FC) sealed switch insert the additional letters
Y
and
C
as in the following
example:
LSA1A - standard side rotary plug-in switch
LS
Y
A
C
1A - completely FC sealed version.
Factory sealed, pre-wired limit switches
have the entry area completely sealed and are available with 6 ft
(1,83 m), STOOW-A cable or 4, 5 or 9-pin connectors. NEMA ratings are, for cable version 1, 4, 6, 6P, 12,
for connector version 1, 4, 6, 6P, 12, 13.
To order a factory sealed switch add the appropriate letter:
Circuitry
Cable
½ in Connector (available with ½ in conduit tap only)
SPDT
C
A
(4 pin mini)
B
(5 pin mini)
DD
(4 pin micro)
DPDT
M
(¾ in only)
R
(9 pin)
Example:
LSA1A
C
- LSA1A with 6 ft of 5 conductor STOOW-A cable
LSJ2B
M
-7N
- LSJ2B-7N with 6 ft of 9 conductor STOOW-A cable
LSA1A
B
- LSA1A with 5 pin receptable
LSA1A
DD
- 4 pin micro-change connector
Electrical ratings
10 amps continuous carry. Circuits on any one pole must be the same polarity.
ac Volts
Pilot duty: 600 Vac, 720 VA
Amps at 0.35 Power Factor
Vac
Make
Break
A
120
60
6
SPDT
240
30
3
NEMA
480
15
1.5
A600
600
12
1.2
B
120
30
3
DPDT
240
15
1.5
NEMA
480
7.5
0.75
B600
600
6
0.60
C
250 Vac or 60 Vdc, 0.050 amp max.
SPDT/DPDT
dc Volts
Pilot duty: 240 Vdc, 30 watts
Make and Break Amps
Vdc
Inductive
Resistive
A
120
0.25
0.8
SPDT
240
0.15
0.4
B
120
0.25
0.8
DPDT
240
0.15
0.4
C
250 Vac or 60 Vdc, 0.050 amp max.
SPDT/DPDT
Levers: Levers for side rotary
types are ordered separately (see
pages 69-71 for details)
Actuators
Содержание Switches and Sensors
Страница 6: ...4 www honeywell com sensing Blank page ...
Страница 28: ...26 www honeywell com sensing COMPACT LIMIT SWITCHES Blank page ...
Страница 47: ...45 www honeywell com sensing HEAVY DUTY LIMIT SWITCHES Operating temperatures Environmental seal performance ...
Страница 56: ...54 www honeywell com sensing Blank page ...
Страница 70: ...68 www honeywell com sensing Blank page ...
Страница 94: ...92 www honeywell com sensing Blank page ...
Страница 118: ...116 www honeywell com sensing LINEAR AND ROTARY POSITION Blank page ...