S8610U UNIVERSAL INTERMITTENT PILOT GAS IGNITION CONTROL
69-1955
8
The following four tables describe the wiring connections necessary for conversion:
Table 5. Conversion from Honeywell Intermittent Pilot Modules.
Terminal
Function
Replacement
Control
Old Control
Procedural Notes
S8610U
S86A,C
S86B,D
S86E,F,G,H
S90A,B
S8600A,B,C
S8610A,B,C
S8610U1003
S8620C,
S8660D,J
S8670D,J
S8680D,J
S8600F,H,M
S8610F,H,M
S8660E,K
S8670E,K
Main Valve
Operator
MV
MV
MV
MV
MV
MV
—
Main Valve
and Pilot
Common
MV/PV
MV/PV
MV/PV
MV/PV
MV/PV
MV/PV
—
Pilot Valve
Operator
PV
PV
PV
PV
PV
PV
—
Burner
Ground
Connection
GND
(BURNER)
GND
GND
GND
(BURNER)
GND (BURNER)
GND (BURNER)
—
Transformer
Secondary
(un-
switched
leg)
24V GND
25V (2)
25V
25V (2)
a
a
Terminals may be marked 25V on some models and 24V on later models. These are functionally equivalent.
24V GND
24V GND
—
Transformer
Secondary
(switched
leg)
24V
*
25V (2)
25V
25V (2)
a
*
24V *
24V
*
* IMPORTANT
If the old module had a
vent damper connector but
a vent damper was not
installed, or if it did not
have a vent damper
connector, then connect
the 25V (2) or 24V wire
from the old module to the
TH-W terminal on the
S8610U. Do not use the
24V terminal on the
S8610U.
If the old module had a
vent damper, connect it to
the P1 connector on the
module, and wire the
terminals as indicated in
the table.
25V (2) or 24V used only in systems where plug-in
cable connects damper to module
TH-W
TH-R
b
b
If 25V (2) and TH-R have wires connected, disconnect and splice together with solderless connector.
TH-R
b
TH-R
b
TH-W
(This terminal is
not included on
S90.)
TH-W
TH-W
c
c
If TH-R and TH-W are jumpered together, connect 25V (2) lead from S86 to TH-W on S8610U.
TH-W
TH-W
c
Flame
Sensor
SENSE
d
d
On dual igniter and sensor models, remove jumper wire quick connect from S8610U Remote Sense terminal, then cut jumper wire at
circuit board and discard.
e
e
Leave black jumper connected.
e
e
SENSE
d
e
—
Igniter /
Sensor
SPARK
IGN COIL
f
f
Use Rajah to quick connector adapter (supplied) or cut Rajah connector off ignition cable at module end and attach insulated quick
connect for connection to S8610U.
IGN COIL
f
IGN COIL
f
SPARK
SPARK
—