Fig. 4
—S8600A,B; S8610A,B with vent damper plug in an atmospheric burner heating system with a D80D vent
damper.
PILOT GAS
SUPPLY
5 REMOVE PLUG ONLY IF USING VENT DAMPER.
M1185D
LIMIT
CONTROLLER
GROUND
IGNITER
1
L2
L1
(HOT)
4 CONTROLS IN 24V CIRCUIT MUST NOT BE IN
GROUND LEG TO TRANSFORMER.
4
3 MAXIMUM CABLE LENGTH 3 FEET [0.9 METERS].
D80D VENT DAMPER
SENSOR
1 POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
2 ALTERNATE LIMIT CONTROLLER LOCATION.
2
DUAL VALVE COMBINATION
GAS CONTROL
THERMOSTAT
197516A
WIRING
HARNESS
1ST
2ND
OPERATOR OPERATOR
MAIN
VALVE
PILOT
COM
3
SENSE
SPARK
5
VENT
DAMPER
PLUG
24V
GND 24V TH-W
S8600A,B; S8610A,B
GND
MV MV/PV PV (BURNER)
M1177C
L2 L1
(HOT)
1
PILOT GAS
SUPPLY
COMBUSTION
1
AIR BLOWER
MOTOR
GROUND
5 FOR MODULE WITH TH-W TERMINAL AND VENT
DAMPER PLUG, CONNECT THERMOSTAT TO TH-W.
LEAVE 24V OPEN. DO NOT REMOVE VENT DAMPER PLUG.
PILOT
BURNER
Q345, Q346,
Q348, Q362, Q381
PILOT BURNER/
IGNITER-SENSOR
LIMIT
CONTROLLER
L2
L1
(HOT)
2 ALTERNATE LIMIT CONTROLLER LOCATION.
3 MAXIMUM CABLE LENGTH 3 ft [0.9 m].
4 CONTROLS IN 24V CIRCUIT MUST NOT BE IN
GROUND LEG TO TRANSFORMER.
4
1 POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
1ST
2ND
OPERATOR OPERATOR
2
DUAL VALVE COMBINATION
GAS CONTROL
COMBUSTION
AIR BLOWER
RELAY
THERMOSTAT
AIR
PROVING
SWITCH
MAIN
PILOT
COM
VALVE
3
5
SPARK
5 VENT
DAMPER
PLUG (OPT)
GND 24V (OPT)
TH-W
24V
GND
MV MV/PV PV (BURNER)
S8600F,H,M; S8610F,H; S8660D; S8670D
Fig. 5
—S8600F,H,M; S8610F,H; S8660D; S8670D connections in a heating system with power-assisted
combustion.