5
69-0463
44 ซ.บรมราชชนนี 70 ถ.บรมราชชนนี ศาลาธรรมสพน์ ทวีวัฒนา กทม. 10170.
Website:
โทร: 02-888-3472
Line ID: @add11 e-mail: [email protected]
Fig. 2
—S8600F,H,M; S8610F,H with a vent damper plug in a heating system with an atmospheric burner and a D80D
vent damper.
M1176D
5 REMOVE PLUG ONLY IF USING VENT DAMPER.
FUSE BLOWS ON STARTUP WHEN PLUG IS REMOVED;
THEN MODULE WILL OPERATE ONLY WHEN VENT
DAMPER IS CONNECTED.
PILOT BURNER
GROUND
PILOT GAS
SUPPLY
Q345, Q346,
Q348, Q362, Q381
PILOT BURNER/
IGNITER-SENSOR
1
4 CONTROLS IN 24V CIRCUIT MUST NOT BE IN
GROUND LEG TO TRANSFORMER.
L1
(HOT)
L2
3 MAXIMUM CABLE LENGTH 3 FEET [0.9 METERS].
LIMIT
4
CONTROLLER
2 ALTERNATE LIMIT CONTROLLER LOCATION.
D80D VENT
DAMPER
2
DUAL VALVE COMBINATION
GAS CONTROL
1 POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
THERMO-
STAT
1ST
2ND
OPERATOR OPERATOR
MAIN
VALVE
PILOT
COM
3
197516A
WIRING
HARNESS
SPARK
DAMPER
PLUG
5 VENT
24V
GND 24V TH-W
S8600F,H,M; S8610F,H
GND
MV MV/PV PV (BURNER)
PILOT GAS
SUPPLY
LIMIT
CONTROLLER
GROUND
IGNITER
1
L2
L1
(HOT)
4
3 MAXIMUM CABLE LENGTH 3 ft [0.9 m].
4 CONTROLS IN 24V CIRCUIT MUST NOT BE IN
GROUND LEG TO TRANSFORMER.
5 FOR MODULE WITH TH-W TERMINAL AND VENT
DAMPER PLUG, CONNECT THERMOSTAT TO TH-W.
LEAVE 24V OPEN. DO NOT REMOVE VENT DAMPER PLUG.
M1186C
SENSOR
AND OVERLOAD PROTECTION AS REQUIRED.
2 ALTERNATE LIMIT CONTROLLER LOCATION.
2
DUAL VALVE COMBINATION
1 POWER SUPPLY. PROVIDE DISCONNECT MEANS
GAS CONTROL
OPERATOR OPERATOR
THERMOSTAT
2ND
1ST
MAIN
PILOT
COM
VALVE
3
5
5 VENT
DAMPER
PLUG (OPT) SENSE SPARK
GND 24V (OPT)
TH-W
24V
S8600A,B; S8610A,B
GND
MV MV/PV PV (BURNER)
Fig. 3
—S8600A,B; S8610A,B connections in a heating system with an atmospheric burner.