STATUS OUTPUT APPLICATION
The lock-out status data from the S4565PV, QV, RV, TV
ignition controls can be read by the microprocessor in the
comfort boiler control and stored in its EEPROM.
The relay contact is controlled by the microprocessor and
activates the S4565PV, QV, RV, TV.
During the start sequence the status output gives status
information of the S4565PV, QV, RV, TV.
The status information can be found under chapter
SPECIFICATIONS paragraph:“Opto coupler status output”
on page 41
If the signal of the status output does not correspond to the
specifications, the comfort boiler control can shut off the
ignition control.
Fig. 58. Status output application
1
2
11 10
12
6
9
5 V
-
+
10 K
EEPROM
Microprocessor
Heat demand
Comfort boiler control
S4565PV, QV, RV, TV
L
LM