ELSTER RABO
®
Rotary Gas Meter
05 Honeywell
Figure 5. Horizontal installation
Figure 6. Vertical installation
Figure 7. Sight glass
Figure 4. Side view
b) Mounting
1)
Always follow your company’s procedures, and
applicable local codes and ordinances.
2)
Ensure gas valves are closed.
3)
Ensure the upstream piping is clean and free of any
debris.
4)
Remove protective caps from meter inlet and outlet prior
to installation.
5)
Ensure the impellers turn freely.
6)
Ensure the direction of flow using the arrow on the
nameplate.
7)
Ensure the meter orientation is correct. Impeller shafts
must be horizontal [Figure 4].
8)
Connect the inlet and outlet pipe flanges using
appropriate bolts and gaskets. Inlet and outlet pipe
flanges should be parallel and should not introduce any
bind on the meter body when tightened.
9)
Level meter to within 1/16" per foot in all directions and
tighten flange bolts evenly (maximum 80ft-lbs).
c) Adding Oil
!
WARNING
Add oil only to the index end of the meter.
1)
Ensure gas valves are closed and meter and piping are
depressurized.
!
WARNING
Failure to depressurize the meter prior to removing
meter and/or components could result in personal
injury and/or property damage.
2)
Remove oil fill plug in the counter end case cover using a
5mm hex key [Figures 5 and 6].
3)
Using the supplied syringe and oil, slowly add oil until
it is +/-1/16" of the center of the sight glass [Figure 7].
DO NOT OVERFILL.
Only use Shell Morlina lubricating oil.
!
WARNING
DO NOT remove any sight glasses. No maintenance
can be performed through these openings.
4)
Reinstall the oil fill plug.
OIL
FILL
OIL
LEVEL
SIGHT
GLASS
OIL
DRAIN
OIL
FILL
OIL
FILL
OIL
FILL
OIL
LEVEL
SIGHT
GLASS
OIL
DRAIN
RABO
®
Rotary Gas Meter
04 Elster Instromet
Figure 5. Horizontal installation
Figure 6. Vertical installation
Figure 7. Sight glass
Figure 4. Side view
b) Mounting
1)
Always follow your company’s procedures, and
applicable local codes and ordinances.
2)
Ensure gas valves are closed.
3)
Ensure the upstream piping is clean and free of any
debris.
4)
Remove protective caps from meter inlet and outlet prior
to installation.
5)
Ensure the impellers turn freely.
6)
Ensure the direction of flow using the arrow on the
nameplate.
7)
Ensure the meter orientation is correct. Impeller shafts
must be horizontal [Figure 4].
8)
Connect the inlet and outlet pipe flanges using
appropriate bolts and gaskets. Inlet and outlet pipe
flanges should be parallel and should not introduce any
bind on the meter body when tightened.
9)
Level meter to within 1/16" per foot in all directions and
tighten flange bolts evenly (maximum 80ft-lbs).
c) Adding Oil
!
WARNING
Add oil only to the index end of the meter.
1)
Ensure gas valves are closed and meter and piping are
depressurized.
!
WARNING
Failure to depressurize the meter prior to removing
meter and/or components could result in personal
injury and/or property damage.
2)
Remove oil fill plug in the counter end case cover using a
5mm hex key [Figures 5 and 6].
3)
Using the supplied syringe and oil, slowly add oil until
it is +/-1/16" of the center of the sight glass [Figure 7].
DO NOT OVERFILL.
Only use Shell Morlina lubricating oil.
!
WARNING
DO NOT remove any sight glasses. No maintenance
can be performed through these openings.
4)
Reinstall the oil fill plug.
OIL
FILL
OIL
LEVEL
SIGHT
GLASS
OIL
DRAIN
OIL
FILL
OIL
FILL
OIL
FILL
OIL
LEVEL
SIGHT
GLASS
OIL
DRAIN
RABO
®
Rotary Gas Meter
04 Elster Instromet
Figure 5. Horizontal installation
Figure 6. Vertical installation
Figure 7. Sight glass
Figure 4. Side view
b) Mounting
1)
Always follow your company’s procedures, and
applicable local codes and ordinances.
2)
Ensure gas valves are closed.
3)
Ensure the upstream piping is clean and free of any
debris.
4)
Remove protective caps from meter inlet and outlet prior
to installation.
5)
Ensure the impellers turn freely.
6)
Ensure the direction of flow using the arrow on the
nameplate.
7)
Ensure the meter orientation is correct. Impeller shafts
must be horizontal [Figure 4].
8)
Connect the inlet and outlet pipe flanges using
appropriate bolts and gaskets. Inlet and outlet pipe
flanges should be parallel and should not introduce any
bind on the meter body when tightened.
9)
Level meter to within 1/16" per foot in all directions and
tighten flange bolts evenly (maximum 80ft-lbs).
c) Adding Oil
!
WARNING
Add oil only to the index end of the meter.
1)
Ensure gas valves are closed and meter and piping are
depressurized.
!
WARNING
Failure to depressurize the meter prior to removing
meter and/or components could result in personal
injury and/or property damage.
2)
Remove oil fill plug in the counter end case cover using a
5mm hex key [Figures 5 and 6].
3)
Using the supplied syringe and oil, slowly add oil until
it is +/-1/16" of the center of the sight glass [Figure 7].
DO NOT OVERFILL.
Only use Shell Morlina lubricating oil.
!
WARNING
DO NOT remove any sight glasses. No maintenance
can be performed through these openings.
4)
Reinstall the oil fill plug.
OIL
FILL
OIL
LEVEL
SIGHT
GLASS
OIL
DRAIN
OIL
FILL
OIL
FILL
OIL
FILL
OIL
LEVEL
SIGHT
GLASS
OIL
DRAIN
RABO
®
Rotary Gas Meter
04 Elster Instromet
Figure 5. Horizontal installation
Figure 6. Vertical installation
Figure 7. Sight glass
Figure 4. Side view
b) Mounting
1)
Always follow your company’s procedures, and
applicable local codes and ordinances.
2)
Ensure gas valves are closed.
3)
Ensure the upstream piping is clean and free of any
debris.
4)
Remove protective caps from meter inlet and outlet prior
to installation.
5)
Ensure the impellers turn freely.
6)
Ensure the direction of flow using the arrow on the
nameplate.
7)
Ensure the meter orientation is correct. Impeller shafts
must be horizontal [Figure 4].
8)
Connect the inlet and outlet pipe flanges using
appropriate bolts and gaskets. Inlet and outlet pipe
flanges should be parallel and should not introduce any
bind on the meter body when tightened.
9)
Level meter to within 1/16" per foot in all directions and
tighten flange bolts evenly (maximum 80ft-lbs).
c) Adding Oil
!
WARNING
Add oil only to the index end of the meter.
1)
Ensure gas valves are closed and meter and piping are
depressurized.
!
WARNING
Failure to depressurize the meter prior to removing
meter and/or components could result in personal
injury and/or property damage.
2)
Remove oil fill plug in the counter end case cover using a
5mm hex key [Figures 5 and 6].
3)
Using the supplied syringe and oil, slowly add oil until
it is +/-1/16" of the center of the sight glass [Figure 7].
DO NOT OVERFILL.
Only use Shell Morlina lubricating oil.
!
WARNING
DO NOT remove any sight glasses. No maintenance
can be performed through these openings.
4)
Reinstall the oil fill plug.
OIL
FILL
OIL
LEVEL
SIGHT
GLASS
OIL
DRAIN
OIL
FILL
OIL
FILL
OIL
FILL
OIL
LEVEL
SIGHT
GLASS
OIL
DRAIN
RABO
®
Rotary Gas Meter
04 Elster Instromet
b) Mounting
c) Adding Oil
Figure 4. Side view
Figure 5. Horizontal installation
Figure 6. Vertical installation
Figure 7. Sight glass
1) Always follow your company’s procedures, and
applicable local codes and ordinances.
2) Ensure gas valves are closed.
3) Ensure the upstream piping is clean and free of any
debris.
4) Remove protective caps from meter inlet and outlet prior
to installation.
5) Ensure the impellers turn freely.
6) Ensure the direction of flow using the arrow on the
nameplate.
7) Ensure the meter orientation is correct. Impeller shafts
must be horizontal [Figure 4].
8) Connect the inlet and outlet pipe flanges using
appropriate bolts and gaskets. Inlet and outlet pipe
flanges should be parallel and should not introduce any
bind on the meter body when tightened.
9) Level meter to within 1/16“ per foot in all directions and
tighten flange bolts evenly (maximum 80ft-lbs).
Add oil only to the index end of the meter.
1) Ensure gas valves are closed and meter and piping are
depressurized.
Failure to depressurize the meter prior to removing
meter and/or components could result in personal
injury and/or property damage.
2) Remove oil fill plug in the counter end case cover using a
5mm hex key [Figures 5 and 6].
3) Using the supplied syringe and oil, slowly add oil until
it is +/-1/16“ of the center of the sight glass [Figure 7].
DO NOT OVERFILL.
Only use Shell Morlina lubricating oil.
DO NOT remove any sight glasses. No maintenance
can be performed through these openings.
4) Reinstall the oil fill plug.
Figure 5. Horizontal installation
Figure 6. Vertical installation
Figure 7. Sight glass
Figure 4. Side view
b) Mounting
1)
Always follow your company’s procedures, and
applicable local codes and ordinances.
2)
Ensure gas valves are closed.
3)
Ensure the upstream piping is clean and free of any
debris.
4)
Remove protective caps from meter inlet and outlet prior
to installation.
5)
Ensure the impellers turn freely.
6)
Ensure the direction of flow using the arrow on the
nameplate.
7)
Ensure the meter orientation is correct. Impeller shafts
must be horizontal [Figure 4].
8)
Connect the inlet and outlet pipe flanges using
appropriate bolts and gaskets. Inlet and outlet pipe
flanges should be parallel and should not introduce any
bind on the meter body when tightened.
9)
Level meter to within 1/16" per foot in all directions and
tighten flange bolts evenly (maximum 80ft-lbs).
c) Adding Oil
!
WARNING
Add oil only to the index end of the meter.
1)
Ensure gas valves are closed and meter and piping are
depressurized.
!
WARNING
Failure to depressurize the meter prior to removing
meter and/or components could result in personal
injury and/or property damage.
2)
Remove oil fill plug in the counter end case cover using a
5mm hex key [Figures 5 and 6].
3)
Using the supplied syringe and oil, slowly add oil until
it is +/-1/16" of the center of the sight glass [Figure 7].
DO NOT OVERFILL.
Only use Shell Morlina lubricating oil.
!
WARNING
DO NOT remove any sight glasses. No maintenance
can be performed through these openings.
4)
Reinstall the oil fill plug.
OIL
FILL
OIL
LEVEL
SIGHT
GLASS
OIL
DRAIN
OIL
FILL
OIL
FILL
OIL
FILL
OIL
LEVEL
SIGHT
GLASS
OIL
DRAIN
RABO
®
Rotary Gas Meter
04 Elster Instromet
Figure 5. Horizontal installation
Figure 6. Vertical installation
Figure 7. Sight glass
Figure 4. Side view
b) Mounting
1)
Always follow your company’s procedures, and
applicable local codes and ordinances.
2)
Ensure gas valves are closed.
3)
Ensure the upstream piping is clean and free of any
debris.
4)
Remove protective caps from meter inlet and outlet prior
to installation.
5)
Ensure the impellers turn freely.
6)
Ensure the direction of flow using the arrow on the
nameplate.
7)
Ensure the meter orientation is correct. Impeller shafts
must be horizontal [Figure 4].
8)
Connect the inlet and outlet pipe flanges using
appropriate bolts and gaskets. Inlet and outlet pipe
flanges should be parallel and should not introduce any
bind on the meter body when tightened.
9)
Level meter to within 1/16" per foot in all directions and
tighten flange bolts evenly (maximum 80ft-lbs).
c) Adding Oil
!
WARNING
Add oil only to the index end of the meter.
1)
Ensure gas valves are closed and meter and piping are
depressurized.
!
WARNING
Failure to depressurize the meter prior to removing
meter and/or components could result in personal
injury and/or property damage.
2)
Remove oil fill plug in the counter end case cover using a
5mm hex key [Figures 5 and 6].
3)
Using the supplied syringe and oil, slowly add oil until
it is +/-1/16" of the center of the sight glass [Figure 7].
DO NOT OVERFILL.
Only use Shell Morlina lubricating oil.
!
WARNING
DO NOT remove any sight glasses. No maintenance
can be performed through these openings.
4)
Reinstall the oil fill plug.
OIL
FILL
OIL
LEVEL
SIGHT
GLASS
OIL
DRAIN
OIL
FILL
OIL
FILL
OIL
FILL
OIL
LEVEL
SIGHT
GLASS
OIL
DRAIN
RABO
®
Rotary Gas Meter