Honeywell Q7055C1053 Скачать руководство пользователя страница 3

Q7055C HONEYWELL METER POINT CONNECT

3

39-00002

BEFORE INSTALLATION

Perform the following steps prior to installing the MPC device:

1.

Verify that the product has been received without dam-

age.

2.

Verify that the correct MPC device has been delivered.

3.

Check the package contents. The following items are

included in each product package:

— Honeywell Meter Point Connect device. 

— 50017367-001 or Model 3A-181WP24, P/N

EMS240075-P5P-SZ Power Supply or SMI18-24-V-P5

Power Supply.

— Honeywell Meter Point Connect Installation Instruc-

tions. 

— Bag of installation materials as follows: one 3-pole

Phoenix power connector, and one or two Phoenix

controller bus channel connectors.

4.

Read the Connections section carefully prior to connect-

ing power, ground and data interface cables to the MPC.

5.

Refer to the installation instructions for each component

connected to the MPC.

Applicable Literature

— Form no. 39-00001, Q7055C1053 MPC-M1 (Single M-

Bus) and Q7055C1055 MPC-M2 (Dual M-Bus) Speci-

fication Data Sheet.

— Form no. 39-00002, Q7055C1053 MPC-M1 (Single M-

Bus) and Q7055C1055 MPC-M2 (Dual M-Bus) Instal-

lation Literature.

— Form no. 39-00003, Q7055C1053 MPC-M1 (Single M-

Bus) and Q7055C1055 MPC-M2 (Dual M-Bus) Config-

uration, Checkout & Test Guide.

— Form no. 39-00004, Q7055C1053 MPC-M1 (Single M-

Bus) and Q7055C1055 MPC-M2 (Dual M-Bus) MPC

Router Installation Guide.

— Form no. 39-00005, Q7055C1053 MPC-M1 (Single M-

Bus) and Q7055C1055 MPC-M2 (Dual M-Bus) Soft-

ware Release Bulletin.

WIRING

CAUTION

Shock Hazard. Removal of the MPC cover can

result in electrical shock

Do not remove cover. There are no user serviceable

parts inside.

Location and Mounting

The MPC device is intended for installation only indoors in a

dry location. It can be mounted in several ways; as a single

device, up to three stacked devices, or wall/cabinet mounted.

Single Device

The following illustration shows the single MPC device

operating position; for example, on a desk (see Fig 2).

Fig. 3. Single Device Operating Position.

Stacked Devices

MPC devices may also be stacked. Because of stability

issues, it is recommended not to stack more than three

devices (see Fig 3).

NOTE: There are cooling slots on the top and bottom of 

the MPC housing.

Fig. 4. Stacked Devices.

 

 Reset     Power 

LAN 

10 

ACT 

Mode 

M-Bus
Ch2

Rx  Tx 

M-Bus
Ch1

Rx  Tx 

100 

Boot  NML

 

M22586

 

 

METER POINT CONNECT MODEL M2

-Bus

 

 Reset     Power 

LAN 

10 

ACT 

Mode 

Rx  Tx 

M-Bus

Ch1

M-Bus

Ch2

Rx  Tx 

100 

Boot  NML

 

 

 Reset     Power 

LAN 

10 

ACT 

Mode 

Rx  Tx 

Rx  Tx 

100 

Boot  NML

 

 

 Reset     Power 

LAN 

10 

ACT 

Mode 

Rx  Tx 

Rx  Tx 

100 

Boot  NML

 

M25115 

M-Bus

Ch1

M-Bus

Ch2

M-Bus

Ch1

M-Bus

Ch2

HONEYWELL

 

METER POINT CONNECT MODEL M2

-Bus

HONEYWELL

 

METER POINT CONNECT MODEL M2

-Bus

HONEYWELL

 

METER POINT CONNECT MODEL M2

-Bus

Содержание Q7055C1053

Страница 1: ...ice providers The Meter Point communicates to sub metering devices via a M Bus level converter using M Bus standards EN13757 3 and EN1434 3 With its combination of scalable performance density and low per port pricing the MPC allows network layer capabilities to be extended to a much wider range of network configurations and environments Customers can now gain the advantages of high performance ne...

Страница 2: ...8 24 V P5 120 240 Vac 50 60 Hz input 24 Vdc 0 8 A output Class 2 Accessories Honeywell Meter Point Connect devices provide RS485 signal interface for bus connection s and require use of level converter device s for conversion of RS485 levels to M Bus voltage levels for connection to meters Following level converters have been tested for use with MPC devices RS485 to M Bus Converters Relay Model PW...

Страница 3: ...0004 Q7055C1053 MPC M1 Single M Bus and Q7055C1055 MPC M2 Dual M Bus MPC Router Installation Guide Form no 39 00005 Q7055C1053 MPC M1 Single M Bus and Q7055C1055 MPC M2 Dual M Bus Soft ware Release Bulletin WIRING CAUTION Shock Hazard Removal of the MPC cover can result in electrical shock Do not remove cover There are no user serviceable parts inside Location and Mounting The MPC device is intend...

Страница 4: ...3 pole Phoenix connectors that are marked for power 2 Fasten them with a small screwdriver 3 Connect a chassis ground to the third position on this connector as marked NOTE The polarity of the 3 pole Phoenix power connector for DC power supplies is don t care Field Bus Connection Ch1 Ch2 The 2 pole Phoenix connectors included are required for connecting the field bus Field bus connection can be co...

Страница 5: ...ection describes the pin layout for the RJ 45 connector Most Ethernet local area networks use twisted pair wiring 10 100BaseT networks are physically laid out in a star topology where each piece of equipment on the network is connected to a central switch The wiring is connected to devices using a plug that resembles a phone jack called RJ 45 See Table 2 on page 5 for details Connect MPC to Switch...

Страница 6: ...h continuously When MPC Bootloader starts to run the Red LED starts to flash When the application firmware begins to run the Green LED starts flashing 4 CH1 Bus Channel 1 activity display This display contains two green LEDs one showing the MPC receive activity Rx and the other showing the MPC transmit activity Tx 5 CH2 Bus Channel 2 activity display This display contains two green LEDs one showin...

Страница 7: ...eld bus channel 1 connection electrically isolated meets EMC and FCC requirements Field Bus wiring is described in the Field Bus Connection Ch1 Ch2 section 11 AC DC IN 24V Power connector for 24 VAC 50 Hz to 60 Hz or 24 VDC power supplies and chassis ground An external power supply is required See the Power Connection section of this document for details 12 RS 232 9 pin SUB D male RS 232 connector...

Страница 8: ...eywell International Inc 39 00002 A A Rev 04 16 Printed in Germany Automation and Control Solutions Honeywell GmbH Boeblinger Straße 17 71101 Schoenaich Germany Honeywell International Inc 1985 Douglas Drive North Golden Valley MN 55422 www honeywell com buildingsolutions ...