Q7055B1047 OPEN VIEW NET SERVER (OVN)

Automation and Control Solutions

Honeywell International Inc.

Honeywell Limited-Honeywell Limitée

1985 Douglas Drive North

35 Dynamic Drive

Golden Valley, MN  55422

Scarborough, Ontario  M1V 4Z9

www.honeywell.com/buildingsolutions

® U.S. Registered Trademark
© 2006 Honeywell International Inc.
95-7711  J.I.   04-06 

Содержание Q7055B1047

Страница 1: ...ice providers With its combination of scalable performance density and low per port pricing the OVN allows network layer capabilities to be extended to a much wider range of network configurations and environments OVN supports a full range of Building Management System BMS features such as commanding of points as well as performing complex functions like alarm and schedule management Advanced feat...

Страница 2: ...0013930 001 Mounting Bracket BEFORE INSTALLATION Perform the following steps prior to installing the OVN server 1 Verify that the product has been received without damage 2 Verify that the correct OVN server has been delivered 3 Check the package contents The following items are included in each product package Building Network Adapter device Building Network Adapter driver software CD Building Ne...

Страница 3: ...own on the desk Remove the four feet from the bottom of the OVN by pushing horizontally away from the housing with a flat screwdriver Push the four inserts included fully and horizontally into the housing Adjust the four retaining clips included on top of the inserts Fasten the retaining clips with the included four screws Use the housing with the clips to mark the positions of the four mounting h...

Страница 4: ...EPARATED FROM ALL NON POWER LIMITED WIRING BY A MINIMUM DISTANCE OF 1 4 IN 6 MM NOTE TYPICAL MOUNTING LOCATIONS FOR 14005680 089582 592 FIBER OPTIC INTERFACE 1 ALL WIRING MUST BE IN ACCORDANCE WITH NFPA 70 NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES 2 G GROUNDING CONDUCTOR 3 GROUND CONNECTION 8 32 STUD WITH 8 32 KEPS NUT 4 GROUND CONNECTION FOR 14507678 SERIES PNET PROTECTOR AND OTHER ...

Страница 5: ... at the end of the cable 2 Strip the two power cable ends and insert each cable end into the openings of the 3 pole Phoenix connectors that are marked for power 3 Fasten them with a screwdriver 4 Connect a chassis ground to the third position on this connector as marked NOTE The polarity of the 3 pole Phoenix power connector for DC power supplies is don t care Field Bus Connection The 2 pole Phoen...

Страница 6: ...AN via an Ethernet Hub the required cable should be configured as shown in Fig 8 Fig 8 Straight through pinning for OVN to Ethernet Hub connections Connect OVN to Workstation When an OVN needs a direct connection to a workstation without using an Ethernet Hub a crossover cable is required Fig 9 shows how the different signals should be connected Fig 9 Crossover pinning for OVN to workstation direc...

Страница 7: ...g at 100 mbps ACTIVITY Link activity indicator Green will blink if there is any activity transmission reception on the LAN 6 AC DC IN 24 V Power connector for 24 Vac 50 Hz to 60Hz or 24 Vdc power supplies and chassis ground Power consumption is 8 VA connected via 10 100BaseT cable An external power supply is required 7 10 100BASET 10 100BaseT RJ 45 Ethernet LAN connector meets the requirements of ...

Страница 8: ... Honeywell International Inc Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 www honeywell com buildingsolutions U S Registered Trademark 2006 Honeywell International Inc 95 7711 J I 04 06 ...