8
Applicator Interface Kit Installation Guide
Applicator Interface IN Signals
The Applicator Interface supports 8 digital input ports with optocouplers. All in
signals are asserted by setting the pin LOW and de-asserted by setting the pin
HIGH.
IN Signals Specification
Simplified schematic of a digital IN port
IN Signals Connector Configuration
Signal
Description
Min.
Typical
Max.
Vin [High]
Input Voltage High
10V
24V
40V
Vin [Low]
Input Voltage Low
-1V
0V
1V
Pin
Signal
Description
10
StartPrint_K
Start print Anode Opto In Channel
40
StartPrint_A
Start print Cathode Opto In Channel
26
Feed_A
Feed Anode Opto In Channel
11
Feed_K
Feed Cathode Opto In Channel
41
Pause_A
Pause Anode Opto In Channel
27
Pause_K
Pause Cathode Opto In Channel
12
Reprint_A
Reprint Anode Opto In Channel
42
Reprint_K
Reprint Cathode Opto In Channel
28
AppErr1_A
Applicator Error 1 Anode Opto In Channel
13
APPErr1_K
Applicator Error 1 Cathode Opto In Channel
43
AppErr2_A
Applicator Error 2 Anode Opto In Channel
29
APPErr2_K
Applicator Error 2 Cathode Opto In Channel
14
AppErr3_A
Applicator Error 3 Anode Opto In Channel
44
APPErr3_K
Applicator Error 3 Cathode Opto In Channel
GND
INA
INK