Applicator Interface Kit Installation Guide
23
Error Messages
ERRNOAPP
Message:
Operation not allowed. Applicator Port disabled.
Cause:
Application send an applicator port command to the printer
and the applicator port is disabled.
Error number:
88
ERRAPP
Message:
Operation not allowed. Applicator Port enabled.
Cause:
Application sent the Fingerprint command PORTOUT(PORT)
ON|OFF on a port used by the applicator port when the
applicator is enabled.
Error number:
89
ERRINPUTON
Message:
Operation not allowed in Direct Protocol
Cause:
Running the PORTOUT.DATAREADY ON|OFF or
PORTIN.<SIGNAL>GOSUB XXX commands when the printer
is set to using Direct Protocol.
Error number:
90
EAPPERR1
Message:
Applicator Error 1
Cause:
AppErr1 in signal detected.
Result:
Activates event in System Health Monitor (SHM).
Error number:
1340
EAPPERR2
Message:
Applicator Error 2
Cause:
AppErr2 in signal detected.
Result:
Activates event in System Health Monitor (SHM).
Error number:
1341